6 List Sequence Measurements
List Sequence Measurements
Preset
0 Hz
Default Unit
Hz
Initial S/W
Revision
A.14.00
Trigger Delay
Example
CALC:FPOW:POW1:DEF "TriggerDelay=0.025"
Notes
The trigger delay parameter sets the time after an external trigger is detected until the measurement is
performed.
Preset
0 s
Range
0 – 1 s
Default Unit
Seconds
Initial S/W
Revision
A.14.00
Trigger Level
Example
CALC:FPOW:POW1:DEF "TriggerLevel=2"
Notes
The trigger level parameter sets the voltage value at which an external trigger is detected.
Preset
1.2 V
Range
–5 to 5 V
Default Unit
Volts
Initial S/W Revision
A.14.00
Trigger Slope
Example
CALC:FPOW:POW1:DEF "TriggerSlope=Negative"
Notes
The trigger slope parameter indicates the direction of the edge trigger voltage for detection.
Preset
Positive
Range
Positive, Negative
Initial S/W Revision
A.14.00
Sequence Analyzer User's & Programmer's Reference
285
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...