3 Input/Output Functions
Input/Output
Example
SENS:CORR:CSET1 ON
Dependencies
Changing this from the OFF state to the ON state automatically turns on "Apply Corrections".
Only the first correction array (Correction 1) supports antenna units. When this array is turned on,
and it contains an Antenna Unit other than “None”, the Y Axis Unit of the analyzer is forced to that
Antenna Unit. All other Y Axis Unit choices are grayed out.
Note that this means that a correction file with an Antenna Unit can only be loaded into the
Corrections 1 register. Consequently only for Correction 1 does the dropdown in the Recall dialog
include.ant, and if an attempt is made to load a correction file into any other Correction register
which DOES contain an antenna unit, a Mass Storage error is generated.
This command will generate an “Option not available” error unless you have the proper option
installed in your instrument.
Preset
Not affected by a Preset. Set to OFF by
Restore Input/Output Defaults
State Saved
Saved in instrument state.
Backwards Compatibility
Notes
Unlike legacy analyzers, Preset does not turn Corrections off (Restore Input/Output Defaults does).
Initial S/W Revision
A.02.00
Modified at S/W Revision
A.14.00
Properties
Accesses a menu that lets you set the properties of the selected correction.
Key Path
Input/Output, Corrections
Initial S/W Revision
A.02.00
Select Correction
Specifies the selected correction. The term "selected correction" is used throughout this document to
specify which correction will be affected by the functions.
Key Path
Input/Output, Corrections
Mode
SA, I/Q Analyzer, Phase Noise, VXA, RTSA, EMI Receiver, DVB-T/H, DTMB, DVB-T/H, DTMB, W-
CDMA, LTE & LTE-Adv FDD, LTE & LTE-Adv TDD, Sequence Analyzer, BTooth
Notes
The selected correction is remembered even when not in the correction menu.
Preset
Set to Correction 1 by Restore Input/Output Defaults
Readback
Correction 1|Correction 2|Correction 3|Correction 4|Correction 5|Correction
6|Correction7|Correction8
Initial S/W Revision
A.02.00
Modified at S/W Revision
x.14.50
Sequence Analyzer User's & Programmer's Reference
103
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...