2 Programming the Test Set
Common Commands
Notes
Registers 0 through 6 are accessible from the front panel in menu keys for Recall Registers.
Min
0
Max
127
Status Bits/OPC
dependencies
The command is sequential.
Initial S/W Revision
Prior to A.02.00
*RST (Remote Command Only)
*RST is equivalent to :SYST:PRES;:INIT:CONT OFF, which is a Mode Preset in the Single measurement
state. This remote command is preferred over Mode Preset remote command - :SYST:PRES, as optimal
remote programming occurs with the instrument in the single measurement state.
Remote Command
*RST
Example
*RST
Notes
Sequential
Clears all pending OPC bits and the Status Byte is set to 0.
Couplings
A *RST will cause the currently running measurement to be aborted and cause the default
measurement to be active. *RST gets the mode to a consistent state with all of the default couplings
set.
Backwards Compatibility
Notes
In legacy analyzers *RST did not set the analyzer to Single, but in the X-Series it does, for compliance
with the IEEE 488.2 specification.
In the X-Series, *RST does not do a *CLS (clear the status bits and the error queue). In legacy
analyzers, *RST used to do the equivalent of SYSTem:PRESet, *CLS and INITiate:CONTinuous OFF.
But to be 488.2 compliant, *RST in the X-Series does not do a *CLS.
Initial S/W Revision
Prior to A.02.00
Save Instrument State
This command saves the current instrument state and mode to the specified instrument memory register.
Remote Command
*SAV <register #>
Example
*SAV 9 Saves the instrument state in register 9.
Notes
Registers 0 through 6 are accessible from the front panel in menu keys for Save Registers.
Min
0
Max
127
Status Bits/OPC
dependencies
The command is sequential.
Initial S/W Revision
Prior to A.02.00
Sequence Analyzer User's & Programmer's Reference
91
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...