6 List Sequence Measurements
List Sequence Measurements
State Saved
No
Initial S/W
Revision
A.14.50
Help Map ID
0
In Sequence Analyzer mode, typical usage would be:
1. LSEQ:WLAN:RADio:STANdard:WLAN AG<== config WLAN radio standard to 801.11AG
2. LSEQ:WLAN:EVM:[setting1] value1<== config WLAN EVM settings in 801.11AG
3. …<== config other WLAN EVM settings in 801.11AG
4. LSEQ:WLAN:SEM:[setting2] value 2<== config WLAN SEM settings in 801.11AG
5. …<== config other WLAN SEM settings in 801.11AG
6. LSEQ:CONF:ADD WLAN “CONFIG_11AG” <== Add and save all current settings of WLAN (now it is in
801.11AG)
7. LSEQ:WLAN:RADio:STANdard:WLAN N40<== config WLAN radio standard to 801.11n 40MHz
8. LSEQ:WLAN:EVM:[setting1] value1<== config WLAN EVM settings in 801.11n 40Mhz
9. …<== config other WLAN EVM settings in 801.11n 40MHz
10. LSEQ:WLAN:SEM:[setting2] value 2<== config WLAN SEM settings in 801.11n 40Mhz
11. …<== config other WLAN EVM settings in 801.11n MHz
12. LSEQ:CONF:ADD WLAN “CONFIG_11n40” <== Add and save all current settings of WLAN (now it is in
801.11n 40Mhz)
13. …<== config the sequence analyzer
14. LSEQ:ACQ1:CONF “CONFIG_11AG”<== apply CONFIG_11AG in acquisition1
15. LSEQ:ACQ2:CONF “CONFIG_11n40”<== apply CONFIG_11n40 in acquisition2
16. INIT
17. FETCh:LSEQ?
18. LSEQ:CONF:CLE<== clear all saved configurations
Measurement Parameter Setup (for measurements from other modes)
These are measurement parameters for a measurement from outside of Sequence Analyzer mode. When
you use a measurement from another mode, the measurement parameters can be set remotely using
SCPI commands, without leaving the Sequence Analyzer mode.
For each “Radio Standard” and “Meas Bitmap” that is set in the Analyzer Sequence table, there are
associated parameters that set up particular measurements. These parameters are globally applied to all
analysis steps over the entire Sequence.
Sequence Analyzer User's & Programmer's Reference
311
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...