6 List Sequence Measurements
List Sequence Measurements
UPPer | RANGe | SMIMo, RFIO1 | RFIO2 | RFIN | RFIO3 | RFIO4
[:SENSe]:LSEQuencer:ACQuire[1]|2|...|4..512:SETup?
Example
:LSEQ:ACQ1 GSM, PGSM, MS, 10, 10, 0dB, LOW, 5ms, 50ms, RFB, –10dBm, 0, NONE, –20, RFIO0, ON,
NORM, RFIO1
:LSEQ:ACQ1?
Notes
The parameters are:
<
enum
> - specifies the Radio Standard for the Acquisition.
<
enum
> - specifies the Radio Band for the Acquisition.
<
enum
> - specifies the DeviceType for the Acquisition.
<
real
> - specifies the Frequency or Channel Number for the Acquisition. The channel number and frequency are
combined to one parameter. If the radio band is set to NONE, this value is interpreted as a frequency value in
Hz. If the radio band is set to a valid band, this value is interpreted as a channel number.
<
integer
> - specifies the Number of Averages for the Acquisition.
<ampl> - specifies the peak expected power in dB for the Acquisition.
<
enum
> - specifies the Instrument Gain for the Acquisition.
<
time
> - specifies the Transition Time for the Acquisition.
<
time
> - specifies the duration of the Acquisition.
<
enum
> - specifies the Input Trigger Type for the Acquisition.
<
ampl
> - specifies the Input Trigger Level for the Acquisition.
<
time
> - specifies the Input Trigger Delay for the Acquisition.
<
enum
> - specifies the Acquisition Output Trigger for the Acquisition.
<relative ampl> - specifies the dB value of Instrument Gain when Instrument Gain is set to LOW. It is Electronic
Attenuation in fact. If Instrument Gain is not set to LOW, this value is ignored. This value is optional. If it is not
set, the default value is used.
<enum> - specify the step Multiport Adapter Input path selection.
<enum> - specify the step Multiport Adapter Preamplify On/Off.
<enum> - specify the Integration type of current acquisition. this is for Span extension and Range extension.
<enum> - specify the acquisition step input path selection.
"Acquisition RF Input Port " on page 434
Dependencies
The range of sub op code values is determined by the number of Acquistions you have configured.
If you attempt to remotely set or query a sub op code that is out of range, this results in an error message.
Initial S/W
Revision
A.05.00
Modified S/W
Revision
A.14.00
Help Map ID
35231
Analysis Step Setup
parameter_table_
23.52941
52.94118
Sequence Analyzer User's & Programmer's Reference
377
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...