6 List Sequence Measurements
Source
Band
Downlink
Uplink
24449
21
1495.9
6450
6450 – 6599
1447.9
24450
24450 –
24599
…
24
1525
7700
7700 – 8039
1626.5
25700
25700 –
26039
25
1930
8040
8040 – 8689
1850
26040
26040 –
26689
26
859
8690
8690 – 9039
814
26690
26690 –
27039
...
Note: The channel numbers that designate carrier frequencies so close to the operating band edges that the carrier extends
beyond the operating band edge shall not be used. This implies that the first 7, 15, 25, 50, 75 and 100 channel numbers at
the lower operating band edge and the last 6, 14, 24, 49, 74 and 99 channel numbers at the upper operating band edge
shall not be used for channel bandwidths of 1.4, 3, 5, 10, 15 and 20 MHz respectively.
LTE TDD Channel Number Ranges
The carrier frequency in the uplink and downlink is designated by the E-UTRA Absolute Radio Frequency
Channel Number (EARFCN) in the range 0 – 65535. The relation between EARFCN and the carrier
frequency in MHz for the downlink is given by the following equation, where FDL_low and NOffs-DL are
given in table 5.4.4–1 and NDL is the downlink EARFCN.
FDL = F 0.1(NDL – NOffs-DL)
The relation between EARFCN and the carrier frequency in MHz for the uplink is given by the following
equation where FUL_low and NOffs-UL are given in table 5.4.4–1 and NUL is the uplink EARFCN.
FUL = F 0.1(NUL – NOffs-UL)
Band
Downlink
Uplink
F
DL_low
(
MHz
)
N
Offs-DL
Range of
N
DL
F
UL_low (
MHz
)
N
Offs-UL
Range of
N
UL
33
1900
36000
36000 –36199
1900
36000
36000 –
36199
34
2010
36200
36200 –36349
2010
36200
36200 –
36349
35
1850
36350
36350 –36949
1850
36350
36350 –
36949
36
1930
36950
36950 –37549
1930
36950
36950 –
37549
37
1910
37550
37550 –37749
1910
37550
37550 –
37749
Sequence Analyzer User's & Programmer's Reference
525
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...