6 List Sequence Measurements
List Sequence Measurements
To facilitate the many measurement global parameters, use of the Measurement Application Modes
parameters is made. The measurement setup sections in
describe each
measurement’s parameters.
If different Info Bandwidths were set for several measurements in an Acquisition then the List Sequencer
has to choose the highest value, acquire the Acquisition data, and then re-sample later if required.
parameter_table_23.53758
52.93301
Key Path
Remote Commands
Help Map ID
0
PVT Meas Setup
"GSM/EDGE PVT Meas Setup" on page 312
"LTE-TDD PVT Meas Setup" on page 313
"TDSCDMA PVT Meas Setup" on page 315
GSM/EDGE PVT Meas Setup
The GSM/EDGE PVT measurement used in the GSM/EDGE mode is used in the Sequencer. The Meas
parameters usable within the List Sequencer measurement are listed below. For complete details of each
parameter, please see the online help associated with the measurement.
The SCPI that is used within the Sequence Analyzer mode is the same as in the GSM/EDGE mode, except
that two additional nodes are required in the Sequence Analyzer mode: one to identify the List Sequencer
measurement and one to identify the mode from which the measurement comes. For example,
[:SENSe]:Epvtime is replaced with [:SENSe]:LSEQuencer:EDGE:EPVTime: or
:CALCulate:LSEQuencer:EDGE:EPVTime:
non_parameter_table_39.50163
6.944445
9.264707
9.264707
15.6781
Command
Description
Notes
[:SENSe]:EPVTime:BANDwidth[:RESolution]
<bandwidth>
[:SENSe]:EPVTime:BANDwidth[:RESolution]?
Info BW
Maximum
is 40MHz
[:SENSe]:EPVTime:BANDwidth[:RESolution]:TYPE
FLATtop|GAUSsian
[:SENSe]:EPVTime:BANDwidth[:RESolution]:TYPE?
Filter Type
[:SENSe]:EPVTime:BSYNc:SOURce
TSEQuence|RFBurst|NONE|RFAMplitude
[:SENSe]:EPVTime:BSYNc:SOURce?
Burst Sync
:CALCulate:EPVTime:LIMit:TEST[:STATe] OFF|ON|0|1
:CALCulate:EPVTime:LIMit:TEST[:STATe]?
Limit Test
[:SENSe]:EPVTime:MASK:SELect STANdard|CUSTom
[:SENSe]:EPVTime:MASK:SELect?
Limit Mask
312
Sequence Analyzer User's & Programmer's Reference
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...