6 List Sequence Measurements
List Sequence Measurements
worst burst.
2
Power averaged is the power (in dBm) of N averaged analysis step intervals, if averaging is on. The power is
averaged across the useful part of the analysis step interval. Average m is a single timeslot from the acquisition. If
there are multiple timeslots in the analysis step interval, only one timeslot is used for average m. This means that N
analysis steps are acquired to make the complete average. If averaging is off, the value of power averaged is the
same as the power single burst value.
3
Start is the index of the data point at the start of the useful part of the burst
4
Stop is the index of the data point at the end of the useful part of the burst
5
T0 is the index of the data point where t0 occurred
6
Burst width is the width of the burst measured at 3 dB below the mean power in the useful part of the burst.
7
Maximum value is the maximum value of the most recently acquired data (in dBm).
8
Minimum value is the minimum value of the most recently acquired data (in dBm).
9
Burst search threshold is the value (in dBm) of the threshold where a valid burst is identified, after the data has been
acquired.
10
1st Error point is the time (in second) which indicates the point on the X Scale where the first failure of a signal was
detected. If the limit passes, returned data has no meaning.
11
Detected TSC is the most recently detected TSC. The returned value is 0~7 (Burst Type : Normal/Higher Symbol
Rate (HSR)) if TSC detected. If TSC not detected, the returned value is –999.0. If Amptd or NONE (Power vs Time
only) specified in Sync Type, the returned value is –999.0. In multi slot condition, the returned value is the detected
TSC of the specified slot(Time Slot ON) or the first evaluated slot(Time Slot OFF).
Note: The returned value in Sync (Synchronization Burst) is.
10 if (BN42, BN43..BN105) = (1,0,1,1,1,0,0,1,0,1,1,0,0,0,1,0,0,0,0,0,0,1,0,0,0,0,0,0,1,
1,1,1,0,0,1,0,1,1,0,1,0,1,0,0,0,1,0,1,0,1,1,1,0,1,1,0,0,0,0,1,1,0,1,1)
11 if (BN42, BN43..BN105) = (1,1,1,0,1,1,1,0,0,1,1,0,1,0,1,1,0,0,1,0,1,0,0,0,0,0,1,1,1,1,1,0,1,
1,1,1,0,1,0,0,0,1,1,1,1,1,1,0,1,1,0,0,1,0,1,1,0,0,0,1,0,1,0,1)
12 if (BN42, BN43..BN105) = (1,1,1,0,1,1,0,0,0,0,1,1,0,1,1,1,0,1,0,1,0,0,0,1,0,1,0,1,1,0,
1,0,0,1,1,1,1,0,0,0,0,0,0,1,0,0,0,0,0,0,1,0,0,0,1,1,0,1,0,0,1,1,1,0)
The returned value in Access (Access Burst) is
20 if (BN8, BN9..BN48) = (0,1,0,0,1,0,1,1,0,1,1,1,1,1,1,1,1,0,0,1,1,0,0,1,1,0,1,0,1,0,1,0,0,0,1,1,1,1,0,0,0)
21 if (BN8, BN9..BN48) = (0,1,0,1,0,1,0,0,1,1,1,1,1,0,0,0,1,0,0,0,0,1,1,0,0,0,1,0,1,1,1,1,0,0,1,0,0,1,1,0,1)
22 if (BN8, BN9..BN48) = (1,1,1,0,1,1,1,1,0,0,1,0,0,1,1,1,0,1,0,1,0,1,1,0,0,0,0,0,1,1,0,1,1,0,1,1,1,0,1,1,1)
12
Detected Mod scheme is the most recently detected modulation scheme. The returned value is as follows.
0 for GMSK, 1 for Normal Burst (NB) 8PSK, 2 for NB 16QAM, 3 for NB 32QAM, 11 for Higher symbol rate Burst
(HB) QPSK, 12 for HB 16QAM, 13 for HB 32QAM
13
Estimated Carrier Power (ECP) in dBm
14
Time Offset Power Results in dB
If averaged number N = 1, the power measured and calculated at Offset Times relative to the mean power across
the useful part of the burst
If averaged number N > 1, Time Offset Results return the limit margin worst case results. That is, 12 time offset
results of the burst which has the worst limit margin are returned
12 Time Offsets can be set by SCPI commands, please see
for details
234
Sequence Analyzer User's & Programmer's Reference
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...