3 Input/Output Functions
Input/Output
Remote Correction Data Set Commands
This section describes the remote (SCPI) commands used to put values into correction sets. See the
correction / table editor section of the Input/Output section for the information on front panel entry of
correction data.
"Set (Replace) Data (Remote Command Only)" on page 113
"Merge Correction Data (Remote Command Only)" on page 113
Set (Replace) Data (Remote Command Only)
The command takes an ASCII series of alternating frequency and amplitude points, each value separated
by commas.
The values sent in the command will totally replace all existing correction points in the specified set.
An Ampcor array can contain 2000 points maximum.
Remote Command
[:SENSe]:CORRection:CSET[1]|2|...|8:DATA <freq>, <ampl>, . . .
[:SENSe]:CORRection:CSET[1]|2|...|8:DATA?
Example
CORR:CSET1:DATA 10000000, –1.0, 20000000, 1.0
This defines two correction points at (10 MHz, –1.0 dB) and (20 MHz, 1.0 dB) for correction set 1.
Preset
Empty after Restore Input/Output Defaults. Survives a shutdown or restart of analyzer application
(including a power cycle).
State Saved
Saved in instrument state.
Min
Freq: 0 Hz
Amptd: –1000 dBm
Max
Freq: 1 THz
Amptd: +1000 dBm
Initial S/W Revision
A.02.00
Modified at S/W Revision
A.14.00
Merge Correction Data (Remote Command Only)
The command takes an ASCII series of alternating frequency and amplitude points, each value separated
by commas. The difference between this command and Set Data is that this merges new correction points
into an existing set.
Any new point with the same frequency as an existing correction point will replace the existing point’s
amplitude with that of the new point.
An Ampcor array can contain 2000 total points, maximum.
Remote Command
[:SENSe]:CORRection:CSET[1]|2|...|8:DATA:MERGe <freq>, <ampl>, ...
Example
CORR:CSET1:DATA:MERGE 15000000, –5.0, 25000000, 5.0
This adds two correction points at (15 MHz, –5.0 dB) and (25 MHz, 5.0 dB) to whatever values
already exist in correction set 1.
Sequence Analyzer User's & Programmer's Reference
113
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...