1 About the Sequence Analyzer Application
What Does the Sequence Analyzer Application Do?
What Does the Sequence Analyzer Application Do?
The Sequence Analyzer mode makes it possible to define, save, and execute a series of data acquisitions
(controlled by the analyzer list sequencer) and/or a series of RF stimulus outputs (controlled by the source
list sequencer). This defined series of acquisitions and/or outputs is known as a sequence.
The test set's source list sequencer and analyzer list sequencer, which are controlled and coordinated by
the Sequence Analyzer mode, allows you to both set up a sequence of data to be output from the test set
and also to set up a sequence of data acquisitions, and define the measurements to be performed on the
data received at the test set input. The sequences are designed for calibration and verification of a mobile
device, and are set up in the test set to correspond exactly with the sequences that are expected at the
mobile device receiver and are generated by the mobile device transmitter, without the need for call
processing.
The flexibility of the list sequencers allows you to set up and make many complex measurements on
defined sets of data, using many different radio standards, all at high speed. It also allows the test set to
be configured to suit the unique requirements of a particular testing situation.
You can run the source list sequencer independently of the analyzer list sequencer (in any mode), but to
run the analyzer and source list sequencers simultaneously, you must be in the Sequence Analyzer mode.
The List Sequencer measurement of the Sequence Analyzer mode actually encompasses several possible
measurements. In addition to the four basic measurements (power, phase & frequency, discrete PAvT, and
IQ data) which are native to the Sequence Analyzer mode, the List Sequencer measurement can make use
of several measurements “borrowed” from other measurement modes. However, in order for the List
Sequencer to use a measurement from another mode, that mode must be licensed on the test set. (For
example, the W-CDMA U9073A application must be licensed on the test set in order for the List Sequencer
to use measurements from the W-CDMA mode.)
36
Sequence Analyzer User's & Programmer's Reference
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...