6 List Sequence Measurements
Source
ARB
Allows you access to the ARB sub-menus.
Key Path
Source, Modulation Setup
Initial S/W Revision
A.05.00
ARB
Allows you to toggle the state of the ARB function. When the ARB is On, a “MOD” annunciator is displayed
in the system settings panel. When the ARB is turned Off, the MOD annunciator is cleared
Key Path
Source, Modulation Setup, ARB
Remote Command
:SOURce:RADio:ARB[:STATe] ON|OFF|1|0
:SOURce:RADio:ARB[:STATe]?
Example
:SOUR:RAD:ARB OFF
:SOUR:RAD:ARB?
Notes
If the ARB is ON, a user then loads or deletes another file to ARB memory, the playing waveform
segment may not keep phase continuity during the ARB memory operation. The waveform will be
replayed after the ARB operation is finished.
Dependencies
This setting is for independent mode and has no effect on
3.3.8 list sequencer mode. Setting
Sequencer to On will put source enter list sequencer mode, and even if
ARB state is On, the ARB file will not be played. Setting
Sequencer to Off
will make source leave list sequencer mode, and this setting will take effect immediately.
The ARB can only be turned on when there is a waveform file selected for playback. On the GUI If no
waveform is selected, this key is grayed out. If you send the SCPI command to turn the ARB on with
no waveform selected for playback, the ARB state remains OFF and an error is generated. “-
When you try to recall a certain set of states in which the selected waveform is not in ARB memory
and the ARB state is On, errors are reported
Couplings
If
AWGN State is On and this setting is On,
RF Power will be adjusted to the value to maintain the AWGN power relationship defined by
"Power Control Mode" on page 558
Power Control Mode and other noise settings
Preset
Off
Range
On | Off
Initial S/W Revision
A.05.00
Modified at S/W Revision
A.16.00 (Add couplings with AWGN state)
Sequence Analyzer User's & Programmer's Reference
549
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...