![Keysight E6650A EXF Скачать руководство пользователя страница 393](http://html1.mh-extra.com/html/keysight/e6650a-exf/e6650a-exf_user-programming-manual_1961647393.webp)
6 List Sequence Measurements
Meas Setup
Avg Frequency Error
"Linear Averaging" on page 393
Max Frequency Error
"Max Hold Averaging" on page 394
IQ Origin Offset
"Linear Averaging" on page 393
(WCDMA only)
IQ Pairs
"Logarithmic Averaging" on page 393
(TDSCDMA only)
Code Domain Power
"Logarithmic Averaging" on page 393
Code Domain Error
"Logarithmic Averaging" on page 393
Phase Discontinuity
Number of slots
Can’t work with averaging, NAN will be returned if Average
Count is set to greated than 1
Repeat for each slot
Phase
Can’t work with averaging, NAN will be returned if Average
Count is set to greated than 1
Repeat for each slot
Phase Discontinuity
Can’t work with averaging, NAN will be returned if Average
Count is set to greated than 1
Repeat for each slot
RMS EVM
Can’t work with averaging, NAN will be returned if Average
Count is set to greated than 1
Repeat for each slot
RMS Magnitude Error
Can’t work with averaging, NAN will be returned if Average
Count is set to greated than 1
Repeat for each slot
RMS Phase Error
Can’t work with averaging, NAN will be returned if Average
Count is set to greated than 1
Repeat for each slot
Frequency Error
Can’t work with averaging, NAN will be returned if Average
Count is set to greated than 1
Repeat for each slot
IQ Original offset
Can’t work with averaging, NAN will be returned if Average
Count is set to greated than 1
(GSM, EDGE, WCDMA,
TD-SCDMA only)
BER
"Linear Averaging" on page 393
Total Bits
Accumulating
Failed Bits
Accumulating
* Power v. Time only averages the measurement results, not the underlying trace; therefore mask limit
testing does not support averaging.
Logarithmic Averaging
Convert all the values to be averaged to linear.
Sum linear values and divide by number of averages.
Convert final value to log.
Linear Averaging
Sum all the values to be averaged and divide by number of averages.
Last Value Averaging
Use the last value of all the results to be averaged.
Sequence Analyzer User's & Programmer's Reference
393
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...