6 List Sequence Measurements
List Sequence Measurements
For more information on each result see the online help for the relevant radio standard measurement
mode.
The SCPI-only header values are as follows:
Meas Bitmap Header is a floating point number which appears ahead of the results for the analysis
interval; it is a decimal representation of the meas bitmap value for the measurements included in the
interval. The value returned for ACP results is 256. If more than one measurement is included in this
analysis step, then the value returned represents the combined meas bitmap value for all included
measurements, and the results are returned in ascending order of their meas bitmap values.
Number Of Results is a floating point number which appears ahead of the results of a measurement within
the analysis interval; it represents the number of results metrics returned by the measurement. The value
returned for ACP results is 75. (Although there are only 3 result index values, each of the results consist of
lists of numbers.)
non_
parameter_
table_
11.30719
66.92811
Index
Result Details
0
Pass/fail results
1. Overall Pass/Fail
Then, returns 24 scalar values of the pass/fail (0.0=pass, 1.0=fail) determined by testing the relative to the
reference carrier and by testing the absolute power limit of the offset frequencies (measured as total power in
dBm)
2. Lower Offset A – relative limit test result
3. Lower Offset A – absolute limit test result
4. Upper Offset A – relative limit test result
5. Upper Offset A – absolute limit test result
6. Lower Offset B – relative limit test result
7. Lower Offset B – absolute limit test result
8. Upper Offset B – relative limit test result
9. Upper Offset B – absolute limit test result
…
22. Lower Offset F – relative limit test result
23. Lower Offset F – absolute limit test result
24. Upper Offset F – relative limit test result
25. Upper Offset F – absolute limit test result
1
Carrier Powers
Returns 3 scalar values representing overall pass/fail, carrier power, and reference carrier power
1. Total Carrier Power
2. Reference Carrier Power
If Meas Type is Total Power Reference, these results are returned in units of dBm. If Meas Type is Power
Spectral Density Reference, these results are returned in units of dBm/Hz or dBm/MHz
2
Power Results
246
Sequence Analyzer User's & Programmer's Reference
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...