6 List Sequence Measurements
List Sequence Measurements
[:SENSe]:EVM:TIME:RESult:MAX <integer>
Max Result
Length
Max Result Length specifies a
maximum result length.
If the auto-detected length is
greater than the specified
maximum result length, the
maximum result length is used
instead
[:SENSe]:EVM:TIME:RESult:SIG OFF|ON|0|1
From SIG
Symbols
For 802.11n, if From SIG Syms
is On:
The result length is detected
from the High Throughput Signal
Field. It compares the decoded
length information to the Max
Result Length parameter and
uses the smaller value as the
measurement result length.
For 802.11n, if From SIG Syms
Off:
When Result Length is Auto, the
analyzer automatically
determines the measurement
result length by burst search. It
compares the detected result
length to Max Result Length
parameter and uses the smaller
value as the measurement result
length.
:CALCulate:EVM:SUBCarrier
ALL|PILOt|SINGle
Subcarrier
This parameter specifies
whether the demodulation
results are for all subcarriers in
the signal, or for a single
subcarrier , or for just the pilot
subcarriers.
:CALCulate:EVM:SUBCarrier:COUNt
<integer>
Subcarrier
Number
This parameter specifies the
demodulation results are for
which subcarrier. When
Subcarrier selects “Single”, this
number will indicate which
subcarrier is used to do
demodulation
[:SENSe]:EVM:FILTer:REFerence:TYPE
GAUSsian|RECT|RC
Reference
Filter
This parameter controls the
reference filter type used when
computing the reference data for
computing EVM
[:SENSe]:EVM:FILTer:ALPHa <real>
Alpha/BT
This parameter is used only
when the Reference Filter is set
to “GAUSSIAN” or “Raised
Cosine”, or the Measurement
334
Sequence Analyzer User's & Programmer's Reference
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...