6 List Sequence Measurements
List Sequence Measurements
11
Off power before is the averaged power between the start time of the analysis interval and the –34th chip before
the burst start time. This value is used for the limit check. The upper limit is –65 dBm. Though limited by analysis
interval, this result is derived from 8960 Tdscdma Transmit ON/OFF Power result: Range 1 OFF Power, whereas it
is the averaged power or the highest chip power between –160th to –34th chips of the averaged trace for TS1, and
–864th to –34th chips of the averaged trace for UpPTS. Please see 3.8.5 of TDSCDMA Meas PD 1131831 for
details.
If average is on and average number is N, this result is calculated after N PVT traces are merged.
12
Average power over –33rd ~ –14th chip is the averaged power between –33rd chip to –14th chip of the burst. This
value is used for the limit check. Its upper limit is –50 dBm. This result is derived from the 8960 Tdscdma Transmit
ON/OFF Power result: Range 2 OFF Power, which is the averaged or highest chip power between –33rd to –14th
chips of the averaged trace. Please see 3.8.5 of TDSCDMA Meas PD 1131831 for details.
If average is on and average number is N, this result is calculated after N PVT traces are merged.
13
Off power after is the averaged power between the 860th chips to the end of the analysis interval. This result is
derived from the 8960 Tdscdma Transmit ON/OFF Power result: Range 3 OFF Power, which is the averaged power
between 860th to 1711st chips of the averaged trace. Please see 3.8.5 of TDSCDMA Meas PD 1131831 for
details.
If average is on and average number is N, this result is calculated after N PVT traces are merged.
14
Max burst start time is the maximum start time of the burst referring to the start of the analysis interval. If
averaging is on and average number is N, this results is the maximum value of the N burst start time results.
IQ Imbalance Result
The IQ Imbalance result (a double) is a value in dB, calculated from Gain Imbalance and Quadrature Skew
as follows:
IQ imbalance is part of the EDGE EVM results, but to preserve backwards compatibility with earlier versions
of firmware it is not included in the general results list. It can be queried using the command:
:FETCh:LSEQuencer:ACQuire{1:512}:ASTep{1:1000}:MEASurement? EEVM, "IqImbalance"
For example, :FETC:LSEQ:ACQ{1}:AST{1}:MEAS? EEVM, "IqImbalance"
parameter_table_23.52941
52.94118
Key Path
Meas
Initial S/W Revision
A.12.50
Help Map ID
0
ACP Results
If the analysis step has requested this measurement then the results returned for the analysis step within
the List Sequencer measurement are listed below.
Sequence Analyzer User's & Programmer's Reference
245
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...