6 List Sequence Measurements
List Sequence Measurements
QPSK EVM measurement returns the following comma-separated scalar results:
non_parameter_
table_15.52288
51.47059
Index
Result Parameter
0
Overall Pass/Fail Result shows the mask test result
0:Pass, 1:Fail, –1:Not tested
1
RMS EVM pass/fail result (1.0 = fail, 0.0 = pass) Returns the result of whether the RMS EVM passed
the limit set in the measurement setup.
2
Reserved result (always return –1.0 )
3
Reserved result (always return –1.0 ).
4
Reserved result (always return –1.0 ).
5
Frequency Error pass/fail result (1.0 = fail, 0.0 = pass) Returns the result of whether the Freq Error
passed the limit set in the measurement setup.
6
Reserved result (always return –1.0 ).
7
RMS EVM (Average) is a floating point number (in percent) of EVM over the entire measurement
interval
8
RMS EVM maximum is the maximum RMS EVM over the average group. If averaging is off, then it
returns result for the measurement interval.
9
Peak EVM is a floating point number (in percent) of the Peak EVM in the measurement interval.
10
Peak EVM maximum is the maximum Peak EVM over the average group. If averaging is off, then it
returns result for the measurement interval.
11
Magnitude Error is a floating point number (in percent) of averaged magnitude error over the entire
measurement interval.
12
Magnitude Error maximum is a floating point number over the average group. If averaging is off, then it
returns result for the measurement interval.
13
Phase Error is a floating point number (in degrees) of the averaged phase error over the entire
measurement interval.
14
Phase Error maximum is the maximum Phase Error over the average group. If averaging is off, then it
returns result for the measurement interval.
15
Frequency Error is a floating point number (in Hz) of the frequency error in the measured signal
16
Frequency Error maximum is the maximum frequency error over the average group. If averaging is off,
then it returns result for the measurement interval.
17
I/Q Origin Offset is a floating point number (in dB) of the I and Q error (magnitude squared) offset from
the origin.
The following QPSK EVM results, which would be returned if the measurement were run in the W-CDMA or
cdma2000 measurement modes, are not returned when the measurement is run in Sequence Analyzer
mode:
•
Unprocessed I/Q Trace Data
•
EVM Trace
•
Magnitude Error Trace
Sequence Analyzer User's & Programmer's Reference
265
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...