6 List Sequence Measurements
Save
Notes
The string must be a valid logical path.
Removes a file from the specified directory. The <file_name> parameter specifies the file name to be
removed. This command will generate an “access denied” error if the file is in a restricted folder (e.g.,
C:\Windows) and the current user does not have Power User or Administrator privileges.
Initial S/W Revision
Prior to A.02.00
Mass Storage Data (Remote Command Only)
Creates a file containing the specified data OR queries the data from an existing file.
Key path
SCPI Only
Remote Command
:MMEMory:DATA <file_name>, <data>
:MMEMory:DATA? <file_name>
Notes
The string must be a valid logical path.
The command form is MMEMory:DATA <file_name>,<data>. It loads <data> into the file <file_
name>. <data> is in 488.2 block format. <file_name> is string data.
The query form is MMEMory:DATA? <file_name> with the response being the associated <data> in
block format.
Initial S/W Revision
Prior to A.02.00
Mass Storage Make Directory (Remote Command Only)
Key path
SCPI Only
Remote Command
:MMEMory:MDIRectory <directory_name>
Notes
The string must be a valid logical path.
Creates a new directory. The <directory_name> parameter specifies the name to be created.
This command will generate an “access denied” error if the new directory would be in a restricted
folder (e.g., C:\Windows) and the current user does not have Power User or Administrator privileges.
Initial S/W Revision
Prior to A.02.00
Mass Storage Move (Remote Command Only)
Key path
SCPI Only
Remote Command
:MMEMory:MOVE <string>,<string>[,<string>,<string>]
Notes
The string must be a valid logical path.
Moves an existing file to a new file or an existing directory to a new directory.
Two forms of parameters are allowed. The first form has two parameters. In this form, the first
parameter specifies the source, and the second parameter specifies the destination.
The second form has four parameters. In this form, the first and third parameters specify the source.
Sequence Analyzer User's & Programmer's Reference
501
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...