background image

UC-280 wireless interface 

1 / 2 

MFT51209 

UC-280 Wireless Interface 

 
 

The  UC-280  is  an  8-zone  interface  linking  JA-60  wireless  detectors 

with  hard-wired  security  control  panels.  It  can  also  send  triggering 
signals to a JA-63A wireless outdoor siren and/or UC-216 and UC-222 
universal  receivers.  Additionally,  it  can  receive  signals  from  Jablotron 
RC-xx remote controls.  

 

 

Installation 

 

The UC-280 is designed and supplied as a PCB module for building 

it  into  other  devices  like  wired  control  panels.  Use  the  supplied    self-
adhesive holders for attaching the PCB to the desired place. 

A  supplied  self-adhesive  antenna  should  be  used  for  the  radio 

module. The antenna should be in a vertical position and should not be 
installed close to any metal structures or other objects obstructing radio 
signal transmissions.   

 

Terminals and connectors 

 

Z1-Z8 

Zone 1-8 output relays’ contacts, max. 100 mA / 60 V, pulse 
length  can  be  set  by  1s/3s  jumper,  normally  closed  or 
normally opened mode is selected by  the NO/NC jumper 

COM1 

common terminal of Z1-Z8 relays 

TMP 

tamper  relay  output   (tamper signal  from  wireless  detectors, 
a  wireless  siren  and  the  UC-280  tamper  switch),  max. 
100 mA / 60 V 

BAT 

low  battery  relay  output  (low  battery  signal  from  wireless 
detectors 1-8 or a wireless siren), max. 100 mA / 60 V 

TRB 

trouble  relay  output  (trouble  signal  from  wireless  detectors 
1-8  or  a  wireless  siren  -  e.g.  lost  communication),  max. 
100 mA / 60 V  

COM2 

common terminal of TMP, BAT and TRB relays 

GND 

power supply ground terminal  

SIR 

triggering  input  for  activation  of  JA-60A  wireless  siren  (the 
siren  sounds  as  long  as  this  input  is  closed  to  GND,  max. 
15 minutes) 

input,  which  can  trigger  relay  X  of  a  UC-216  or  UC-222 
universal receiver when switched to GND 

input,  which  can  trigger  relay  Y  of  a  UC-216  universal 
receiver when switched to GND 

OUT 

input,  which  can  trigger  output  OUT  of  a  UC-216  universal 
receiver when switched to GND  

+12V 

power voltage terminal  

 

ANT 

antenna connector  

 

 

Setting buttons: 

 

LEARN 

if  this  button  is  briefly  pressed,  you  can  scroll  through 
the learning modes of Z1-Z8 zones and a wireless siren 
SIR  (a  selected  channel  is  indicated  by  a  red  flashing 
LED). When this button is pressed for more than 3 sec., 
the enrolling signal for a UC-216 / UC-222 receiver will 
be  transmitted  (learning  mode  of  Z1-Z8  and  SIR  must 
be closed first) 

RESET  

if  this  button  is  briefly  pressed,  the  learning  mode  of  a 
selected  zone  will  be  closed.  When  this  button  is 
pressed  for  more  than  3  sec.,  a  selected  zone  will  be 
deleted  (confirmed  by  flashing  of  the  TMP,  BAT  and 
TRB  indicators).  When  this  button  is  pressed  for  more 
than  6  sec.,  all  zones  will  be  deleted  (confirmed  by 
flashing  of  all  indicators).  Note,  in  order  to  delete  all 
zones,  a  learning  mode  of  any  zone  must  be  selected 
first. 

 

Jumpers: 

 

1s / 3s 

pulse length of 1 sec. or 3 sec. of Z1-Z8 output relays 

NO / NC 

normally  closed  or  normally  opened  mode  of  Z1-Z8 
output relays (TMP, BAT and TRB are normally closed) 

Supervision  regular  checking  of  wireless  detectors’  communication 

can  be  disabled  (NO  SUPERVISION  position).  This 
setting  is  recommended  in  places  with  radio 
interferences.  When  the  supervision  is  enabled,  lost 
communication will trigger the TRB output relay. 

 

Indicators: 

POWER  

The  green  LED  indicates  the  presence  of  the  power 
supply 

 

Z1 Z8,    

LED lights green when zone is occupied; 

 

 

LED lights red when zone detector is triggered; 

 

 

LED flashes red, when zone is in a learning mode; 

 

 

LED  flashes  red  together  with  the  TMP,  BAT  or  TRB 
LED = tamper, low battery or trouble signal in zone  

 

TMP  

tamper  alarm  –  flashes  together  with  a  corresponding 
zone indicator every 3 sec. 

 

BAT  

low  battery  -  flashes  together  with  a  corresponding 
zone indicator every 3 sec. 

 

TRB  

trouble  or  lost communication  -  flashes together  with  a 
corresponding zone or SIR indicator every 3 sec. 

 
 
 
 
 

SIR

 

Antenna

connector

Отзывы: