6 List Sequence Measurements
Source
Delete Segment From ARB Memory
This key functions the same as
"Delete Segment From ARB Mem" on page 625
.
Key Path
Source, List Sequencer, List Sequencer Setup, Waveform, Segments in ARB Memory, Segment in
ARB Memory
Initial S/W Revision
Prior to A.09.00
Delete All From ARB Memory
This key functions the same as
"Delete All From ARB Memory" on page 625
Key Path
Source, List Sequencer, List Sequencer Setup, Waveform, Segments in ARB Memory, Segment in
ARB Memory
Initial S/W Revision
Prior to A.09.00
Step Duration
Allows access to the sub-menus for setting up the duration of play for the current step.
The duration can be set to be either the number of times for the ARB file associated with the sequence to
play, or a specific time value, or continuous. If the step is set to play a CW tone, the step duration cannot
be set to a play count.
Key Path
Source, List Sequencer, List Sequencer Setup
Remote Command
:SOURce:LIST:STEP[1]|2|3…1000:SETup:DURation:TYPE TIME | COUNt |
CONTinuous | CABort
:SOURce:LIST:STEP[1]|2|3…1000:SETup:DURation:TYPE?
Example
:SOUR:LIST:STEP2:SET:DUR:TYPE TIME
:SOUR:LIST:STEP2:SET:DUR:TYPE?
Notes
SCPI is supported after A.09.40
Notes
If “Step Duration” is set to “Time” or “Play Count” for the last step, the last step of ARB keeps playing
as if set to “Continuous”, until the set “Time” has expired or until the “Play Count” setting is reached.
However, you can query
Error! Reference source not found.
Source Sweeping Condition Message to
find out if the current list sequence is complete or not.
Range
Time | Play Count | Continuous | Continuous Abort
Initial S/W Revision
A.05.00
Time
Sets the duration of the current step to be a time value for the length of time the step will play. Pressing
this key again opens another menu which allows you to set the time value for the step duration.
Sequence Analyzer User's & Programmer's Reference
627
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...