6 List Sequence Measurements
Source
Restart on Trigger
Selects Restart on Trigger as the trigger response for single trigger type. Restart on Trigger sets the
waveform generator to play a waveform sequence or segment once when a trigger is received. If a trigger
is received during playback, the waveform generator resets and plays the sequence or segment from the
start.
Key Path
Source, Modulation Setup, ARB, Trigger Type, Single
Example
:SOUR:RAD:ARB:RETR IMM
Initial S/W Revision
A.05.00
Segment Advance
Sets the active trigger type to Segment Advance. If Segment Advance is already selected as the active
trigger type, pressing this key allows access to the segment advance trigger type setup menu.
Segment Advance triggering allows you to control the playback of waveform segments within a waveform
sequence. When a trigger is received the ARB advances to the next waveform segment within the
waveform sequence. This type of triggering ignores the repetition count for the waveform segment within
the waveform sequence. For example, if a waveform segment has a repetition count of 10 and you select
single segment advance triggering mode, the waveform segment will only play once.
Segment Advance triggering can also be used for waveform segments only. In this situation the same
waveform segment is played again when a trigger is received.
Key Path
Source, Modulation Setup, ARB, Trigger Type
Remote Command
:SOURce:RADio:ARB:TRIGger:TYPE:SADVance[:TYPE] SINGle | CONTinuous
:SOURce:RADio:ARB:TRIGger:TYPE:SADVance[:TYPE]?
Example
:SOUR:RAD:ARB:TRIG:TYPE:SADV SING
Preset
CONTinuous
Range
Single | Continuous
Initial S/W Revision
A.05.00
Single
Selects Single as the trigger response for Segment Advance trigger type. With single selected, once a
trigger is received a segment is played once. If a trigger is received during playback of a segment, the
segment plays to completion and the next segment is played once.
Key Path
Source, Modulation Setup, ARB, Trigger Type, Segment Advance
Example
:SOUR:RAD:ARB:TRIG:TYPE:SADV SING
Initial S/W Revision
A.05.00
Sequence Analyzer User's & Programmer's Reference
563
Содержание E6650A EXF
Страница 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...
Страница 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...
Страница 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...
Страница 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...
Страница 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...
Страница 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...
Страница 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...
Страница 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...
Страница 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...