6-4
6-5
Chapter
6
SAFETY
I/O INTERF
ACE
■
Emergency stop input signal connection (2)
Connection when using the RPB-E (provided with an enable switch) with an external
emergency stop circuit
Selector
13
14
RPB connector
SAFETY
connector
13 E-STOPIN1
11 E-STOP24V
12 E-STOPRDY
RPB-E
External emergency
stop circuit
DC24V
GND24V
Main power supply
control circuit
Control signal
detection circuit
L
N
Motor drive
circuit
Internal control
circuit
15
16
17
18
19
20
21
22
14 E-STOPIN2
10
1 DI.COM
3 SERVICE
External service mode
stop circuit
Enable switch
8 KEY1
9 KEY2
1. SAFETY I/O interface overview
Summary of Contents for RCX222
Page 1: ...RCX222 EUR2153130 E99 Ver 1 30 Userʼs Manual YAMAHA 2 AXIS ROBOT CONTROLLER ...
Page 2: ......
Page 14: ......
Page 43: ......
Page 46: ......
Page 50: ...4 MEMO ...
Page 51: ...Chapter 1 USING THE ROBOT SAFELY Contents 1 Operating environment 1 1 ...
Page 52: ......
Page 56: ......
Page 98: ......
Page 388: ......
Page 412: ...5 24 MEMO ...
Page 414: ......
Page 430: ......
Page 442: ......
Page 450: ...8 8 MEMO ...
Page 452: ......
Page 523: ......