Emergency stop input signal connection (3)
Connection when using the standard RPB with an external emergency stop circuit
13
14
RPB connector
SAFETY
connector
13 E-STOPIN1
11 E-STOP24V
12 E-STOPRDY
RPB
External emergency stop
circuit
DC24V
Main power supply
control circuit
Control signal
detection circuit
L
N
Motor drive
circuit
Internal control
circuit
15
16
17
18
19
20
14 E-STOPIN2
1 DI.COM
3 SERVICE
External service mode stop
circuit
External 24V
power supply
1. SAFETY I/O interface overview