12. "SYSTEM" mode
4. DO cond. on EMG /EMGCDO
This parameter sets whether or not to hold output of the DO/MO/LO/TO/SO ports
when an emergency stop signal is input to the controller. This is automatically set to
"HOLD" when the parameters are initialized.
c
CAUTION
This parameter is invalid if the sequence program starts up.
[Procedure]
1) Select "4. DO cond. on EMG " in "SYSTEM>PARAM>OTHERS" mode.
2) Press
(EDIT).
The function key menu changes.
■
Setting "DO cond. on EMG"
SYSTEM
>PARAM>OTHERS
V9.08
1.Display language(JPN/ENG) ENGLISH
2.Data display length 6char
3.Parameter display unit PULSE
4.DO cond. on EMG HOLD
5.Incremental Mode INVALID
RESET
HOLD
3) Press
(RESET) or
(HOLD).
4) Press
to quit the edit mode.