12. "SYSTEM" mode
15. Skip undefined parameters
There are cases where new parameters are added according to the software upgrading
for robot controllers. If you attempt to load the parameter file containing these
new parameters into a controller of an earlier version, an error "10.14 Undefined
parameters" occurs.
If this parameter is set to "VALID", the undefined parameters (newly added
parameters) in the file will then be ignored.
This parameter is not contained in the parameter file and is always set to "INVALID"
each time the power to the controller is turned on.
c
CAUTION
If this parameter is set to "vALID", then misspellings in the parameter file
cannot be detected. Do not use this function except for cases in which you
must load the parameters of a new version into a controller of an earlier
version.
[Procedure]
1) Select "15. Skip undefined parameters" in "SYSTEM>PARAM>OTHERS" mode.
2) Press
(EDIT).
The function key menu changes.
■
Setting "Skip undefined parameters"
SYSTEM
>PARAM>OTHERS
V9.2 3
15.Skip undefined parameters INVALID
12.Manual move mode NORMAL
11.Servo on when power on YES
13.DO cond. on PGM reset RESET
14.Echo point No. NO
INVALID VALID
3) Press
(INVALID) or
(VALID).
4) Press
to quit the edit mode.
Summary of Contents for RCX222
Page 1: ...RCX222 EUR2153130 E99 Ver 1 30 Userʼs Manual YAMAHA 2 AXIS ROBOT CONTROLLER ...
Page 2: ......
Page 14: ......
Page 43: ......
Page 46: ......
Page 50: ...4 MEMO ...
Page 51: ...Chapter 1 USING THE ROBOT SAFELY Contents 1 Operating environment 1 1 ...
Page 52: ......
Page 56: ......
Page 98: ......
Page 388: ......
Page 412: ...5 24 MEMO ...
Page 414: ......
Page 430: ......
Page 442: ......
Page 450: ...8 8 MEMO ...
Page 452: ......
Page 523: ......