4-4
Chapter
4
OPERA
TION
4-5
t
Selector switch (RPB-E only)
This switch can be used as needed by wiring to the SAFETY connector by the user.
The switch ON/OFF function is disabled if not wired correctly.
y
3-position enable switch (RPB-E only)
This switch is provided for safety. Pressing it to mid-position only allows robot
operation.
This switch does not function unless pins 1 to 4 (for enable switch) of the SAFETY
connector are correctly wired.
Switch is released
: Emergency stop.
Switch is pressed to mid position : Operation possible
Switch is fully pressed
: Emergency stop
Configure the external safety circuit so that this enable switch functions as described
above.
3.3 Connection to the robot controller
Connect the RPB programming box to the RPB connector on the front panel of the robot
controller.
Connect the cable securely since poor connections might cause malfunctions or
breakdowns.
n
NOTE
Emergency stop is triggered when the RPB is connected to or disconnected
from the robot controller while the power is on. If this happens, emergency
stop must be cancelled to continue operation.
■
Robot controller connection
XM
YM
MOTOR
RGEN
TEMP
ACIN
N
L
L1
N1
SAFETY
SRV
ERR
RPB
ROB
I/O
SD/COM
RDY
E-STOP
B/A
BAT
RCX222
PIN11-12
EXT.E-STOP
OP.1
OP.2
!
RPB programming box
RPB connector
3. RPB programming box
Summary of Contents for RCX222
Page 1: ...RCX222 EUR2153130 E99 Ver 1 30 Userʼs Manual YAMAHA 2 AXIS ROBOT CONTROLLER ...
Page 2: ......
Page 14: ......
Page 43: ......
Page 46: ......
Page 50: ...4 MEMO ...
Page 51: ...Chapter 1 USING THE ROBOT SAFELY Contents 1 Operating environment 1 1 ...
Page 52: ......
Page 56: ......
Page 98: ......
Page 388: ......
Page 412: ...5 24 MEMO ...
Page 414: ......
Page 430: ......
Page 442: ......
Page 450: ...8 8 MEMO ...
Page 452: ......
Page 523: ......