HX7+ ASD Installation and Operation Manual
89
FL Output Terminal Assignment
Program
Terminal Selection
Output Terminal
This parameter sets the functionality of the
FL
output terminals to 1 of the 62
possible functions that are listed in
.
The on and off delay times of the
FL
terminals may be adjusted to provide
more response time to the device that is connected to the output terminals.
In addition, the output terminals must be specified as
Normally Open
or
Normally Closed
.
Direct Access Number — F132
Parameter Type —
Selection List
Factory Default —
Fault (All)
Changeable During Run —
No
Output #4 Terminal Assignment
Program
Terminal Selection
Output Terminal
This parameter sets the functionality of the
OUT4
terminals to 1 of the 62
possible functions that are listed in
.
The on and off delay times of the
OUT4
terminals may be adjusted to provide
more response time to the device that is connected to the output terminals.
In addition, the output terminals must be specified as
Normally Open
or
Normally Closed
.
Direct Access Number — F133
Parameter Type —
Selection List
Factory Default —
LL
Changeable During Run —
No
OUT5 Terminal Assignment
Program
Terminal Selection
Output Terminal
This parameter sets the functionality of the
OUT5
terminals to 1 of the 62
possible functions that are listed in
.
The on and off delay times of the
OUT5
terminals may be adjusted to provide
more response time to the device that is connected to the output terminals.
In addition, the output terminals must be specified as
Normally Open
or
Normally Closed
.
Direct Access Number — F134
Parameter Type —
Selection List
Factory Default —
UL
Changeable During Run —
No
OUT6 Terminal Assignment
Program
Terminal Selection
Output Terminal
This parameter sets the functionality of the
OUT6
terminals to 1 of the 62
possible functions that are listed in
.
The on and off delay times of the
OUT6
terminals may be adjusted to provide
more response time to the device that is connected to the output terminals.
In addition, the output terminals must be specified as
Normally Open
or
Normally Closed
.
Direct Access Number — F135
Parameter Type —
Selection List
Factory Default —
RCH (Specified
Speed)
Changeable During Run —
No
Summary of Contents for HX7+ ASD
Page 2: ...DN 67017 001 February 2014 HX7 ASD Installation Operation Manual ...
Page 227: ...218 HX7 ASD Installation and Operation Manual Figure 35 200 kVA Sine Wave NEMA 1 Enclosure ...
Page 231: ...222 HX7 ASD Installation and Operation Manual Figure 39 200 kVA Sine Wave NEMA 3R Enclosure ...
Page 235: ...226 HX7 ASD Installation and Operation Manual Figure 43 66 163 kVA 18 Pulse Enclosure ...
Page 236: ...HX7 ASD Installation and Operation Manual 227 Figure 44 200 kVA 18 Pulse Enclosure ...
Page 237: ...228 HX7 ASD Installation and Operation Manual Figure 45 260 518 kVA 18 Pulse Enclosure ...
Page 238: ...HX7 ASD Installation and Operation Manual 229 Figure 46 518 700 kVA 18 Pulse Enclosure ...