HX7+ ASD Installation and Operation Manual
187
Communications Speed Frequency #1
Program
Communication
Communication Reference Adjust
This parameter is used to set the gain and bias of the
Communications
Reference
speed control input.
See
for further information on this setting.
This parameter sets
Communications Speed Frequency #1
and is the
frequency that is associated with the setting of
Communications Speed
Reference #1
.
Changes made to this parameter require that the power be cycled (Off then On)
for the changes to take effect.
Direct Access Number — F812
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum —
Max. Freq.
Units — Hz
Communications Speed Reference #2
Program
Communication
Communication Reference Adjust
This parameter is used to set the gain and bias of the
Communications Speed
Reference #2
speed control input.
See
for further information on this setting.
This parameter sets the
Communications Speed Reference #2
input value that
represents
Communications Speed Frequency #2
. This value is entered as 0 to
100% of the
Communications Speed Reference #2
input value range.
Changes made to this parameter require that the power be cycled (Off then On)
for the changes to take effect.
Direct Access Number — F813
Parameter Type —
Numerical
Factory Default —
100.0
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 100.0
Units — %
Communications Speed Frequency #2
Program
Communication
Communication Reference Adjust
This parameter is used to set the gain and bias of the
Communications Speed
Reference
#2
speed control input.
See
for further information on this setting.
This parameter sets
Communications Speed Frequency #2
and is the
frequency that is associated with the setting of
Communications Speed
Reference #2
.
Changes made to this parameter require that the power be cycled (Off then On)
for the changes to take effect.
Direct Access Number — F814
Parameter Type —
Numerical
Factory Default —
80.0
Changeable During Run —
Yes
Minimum — 0.0
Maximum —
Max. Freq.
Units — Hz
RS232/RS485 Baud Rate
Program
Communication
Communication Settings
This parameter sets the RS232/RS485 baud rate.
Changes made to this parameter require that the power be cycled (Off then On)
for the changes to take effect.
Settings:
0 — 1200
1 — 2400
2 — 4800
3 — 9600
4 — 19200
5 — 38400
Direct Access Number — F820
Parameter Type —
Selection List
Factory Default —
9600
Changeable During Run —
Yes
Summary of Contents for HX7+ ASD
Page 2: ...DN 67017 001 February 2014 HX7 ASD Installation Operation Manual ...
Page 227: ...218 HX7 ASD Installation and Operation Manual Figure 35 200 kVA Sine Wave NEMA 1 Enclosure ...
Page 231: ...222 HX7 ASD Installation and Operation Manual Figure 39 200 kVA Sine Wave NEMA 3R Enclosure ...
Page 235: ...226 HX7 ASD Installation and Operation Manual Figure 43 66 163 kVA 18 Pulse Enclosure ...
Page 236: ...HX7 ASD Installation and Operation Manual 227 Figure 44 200 kVA 18 Pulse Enclosure ...
Page 237: ...228 HX7 ASD Installation and Operation Manual Figure 45 260 518 kVA 18 Pulse Enclosure ...
Page 238: ...HX7 ASD Installation and Operation Manual 229 Figure 46 518 700 kVA 18 Pulse Enclosure ...