HX7+ ASD Installation and Operation Manual
33
HX7+ ASD Control
The Control PCB (
)
serves as the primary control source for the
HX7+ ASD
. The Control PCB
receives input from the
Terminal Board
(see
, RS232/RS485
Communications, or the keypad.
The Control PCB has been enhanced to support two additional functions: Multiple Protocol
Communications and the ability to communicate in either half- or full-duplex modes.
Using the optional multiple-protocol communications interface; the ASD-NANOCOM, the Control
PCB may be configured for the type of communications protocol being received and respond
appropriately to the sending device. The ASD-NANOCOM connects to the
J4
and
J5
connectors
(see
). Jumper PCB (P/N 55365) is required at the
J4
connector if not using the ASD-
NANOCOM.
The ASD-NANOCOM must be setup to support the desired communications protocol via Program
Communication
Communication Settings
. Consult the ASD-NANOCOM User Manual
(P/N 10572-1.000-000) for a complete listing of the setup requirements.
Half or Full duplex communications is available when using RS232/RS485 communications. The
jumpers at the
JP1
and the
JP2
connectors may be moved from one position to the other to facilitate
either half- or full-duplex operation. If no jumpers are used the system will operate in the full duplex
mode.
For more information on the HX7+ ASD communication requirements, please visit
www.tic.toshiba.com/ind/ to acquire a copy of the 7-Series Communications User Manual and visit
www.iccdesigns.com to acquire a copy of the ASD-NANOCOM User Manual.
Contact your Toshiba Customer Support Center if more information is required on the ASD-
NANOCOM.
Figure 9. Control Board of the HX7+ ASD.
25-pin D-type connector.
Connects to the Terminal
Board
(CN7)
.
RS232/RS485
signal I/O (
CNU1
)
Keypad connection
and TTL I/O
(
CNU2
)
CNU3
CN2
CN8
CNU4
JP1/JP2 Jumpers - Half-/Full-Duplex Selection
RS232/RS485
signal I/O (
CN3)
ASD-NANOCOM
Sink/Source
Switching
J5
J4
Summary of Contents for HX7+ ASD
Page 2: ...DN 67017 001 February 2014 HX7 ASD Installation Operation Manual ...
Page 227: ...218 HX7 ASD Installation and Operation Manual Figure 35 200 kVA Sine Wave NEMA 1 Enclosure ...
Page 231: ...222 HX7 ASD Installation and Operation Manual Figure 39 200 kVA Sine Wave NEMA 3R Enclosure ...
Page 235: ...226 HX7 ASD Installation and Operation Manual Figure 43 66 163 kVA 18 Pulse Enclosure ...
Page 236: ...HX7 ASD Installation and Operation Manual 227 Figure 44 200 kVA 18 Pulse Enclosure ...
Page 237: ...228 HX7 ASD Installation and Operation Manual Figure 45 260 518 kVA 18 Pulse Enclosure ...
Page 238: ...HX7 ASD Installation and Operation Manual 229 Figure 46 518 700 kVA 18 Pulse Enclosure ...