HX7+ ASD Installation and Operation Manual
115
BIN Speed Frequency #1
Program
Frequency Setting
Speed Reference Setpoints
BIN
This parameter is used to set the gain and bias of the binary input when the
discrete input terminals are used as the control input while operating in the
Speed Control
mode.
This parameter sets
BIN Speed Frequency #1
and is the frequency that is
associated with the setting of
BIN Speed Reference #1
while operating in the
Speed Control
mode.
See
BIN Speed Reference #1
) for further information on this setting.
Direct Access Number — F229
Parameter Type —
Numerical
Factory Default —
0.0
Changeable During Run —
Yes
Minimum — -
Max. Freq.
(
Maximum —
Max. Freq.
Units — Hz
BIN Speed Reference #2
Program
Frequency Setting
Speed Reference Setpoints
BIN
This parameter is used to set the gain and bias of the binary input when the
discrete input terminals are used as the control input while operating in the
Speed Control
mode or the
Torque Control
mode.
See
BIN Speed Reference #1
for further information on this setting when used
for
Speed
control or
Torque
control.
This parameter sets
BIN Speed Reference #2
and is the input signal that is
associated with the setting of
BIN Speed Frequency #1
while operating in the
Speed Control
mode or is associated with the
BIN Torque Reference Setpoint
#2
while operating in the
Torque
control mode.
Direct Access Number — F230
Parameter Type —
Numerical
Factory Default —
100.00
Changeable During Run —
Yes
Minimum — 0.0
Maximum — 100.0
Units — %
BIN Speed Frequency #2
Program
Frequency Setting
Speed Reference Setpoints
BIN
This parameter is used to set the gain and bias of the binary input when the
discrete input terminals are used as the control input while operating in the
Speed Control
mode.
This parameter sets
BIN Speed Frequency #2
and is the frequency that is
associated with the setting of
BIN Speed Reference #1
while operating in the
Speed Control
mode.
See
BIN Speed Reference #1
) for further information on this setting.
Direct Access Number — F231
Parameter Type —
Numerical
Factory Default —
80.00
Changeable During Run —
Yes
Minimum — -
Max. Freq.
(
Maximum —
Max. Freq.
Units — Hz
BIN Torque Reference Setpoint #1
Program
Torque Setting
Setpoints
BIN
This parameter is used to set the gain and bias of the binary input when the
discrete input terminals are used as the control input while operating in the
Torque Control
mode.
This is accomplished by establishing an associated
V/f
output pattern for a
given binary input signal.
See
BIN Speed Reference #1
for further information on this setting.
This parameter sets
BIN
Torque Reference Setpoint #1
and is the output
torque value that is associated with the setting of
BIN Speed Reference #1
while operating in the
Torque
control mode.
Direct Access Number — F232
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — -250.0
Maximum — 250.0
Units — %
Summary of Contents for HX7+ ASD
Page 2: ...DN 67017 001 February 2014 HX7 ASD Installation Operation Manual ...
Page 227: ...218 HX7 ASD Installation and Operation Manual Figure 35 200 kVA Sine Wave NEMA 1 Enclosure ...
Page 231: ...222 HX7 ASD Installation and Operation Manual Figure 39 200 kVA Sine Wave NEMA 3R Enclosure ...
Page 235: ...226 HX7 ASD Installation and Operation Manual Figure 43 66 163 kVA 18 Pulse Enclosure ...
Page 236: ...HX7 ASD Installation and Operation Manual 227 Figure 44 200 kVA 18 Pulse Enclosure ...
Page 237: ...228 HX7 ASD Installation and Operation Manual Figure 45 260 518 kVA 18 Pulse Enclosure ...
Page 238: ...HX7 ASD Installation and Operation Manual 229 Figure 46 518 700 kVA 18 Pulse Enclosure ...