HX7+ ASD Installation and Operation Manual
57
Input Power
— Displays the
Input Power
in Kilowatts (Kw).
Output Power
— Displays the
Output Power
in Kilowatts (Kw).
Peak Current
— Displays the
Peak Current
since the last start was initiated. The current is
displayed as a percentage of the rated capacity of the HX7+.
Peak Voltage
— Displays the
Peak Voltage
since the last start was initiated. The voltage is
displayed as a percentage of the rated capacity of the HX7+.
PG Speed
— Displays the
PG Speed
.
Direction
— Displays the
Direction
command (forward/reverse).
PG Position
— Displays the
Pulse Generator Position
.
RR
— Displays the
RR
input value as a percentage of the full range of the RR value (potentiometer
input).
*VI/II
— Displays the
VI/II
input setting as a percentage of the full range of the
VI/II
value.
Note:
* The
VI/II
input represents two analog inputs (and terminals). The
VI
input
terminal is used for a 0 – 10 VDC analog signal and the
II
input terminal is used
for current loop applications, such as with a 4-20 mA signal. Either may be used
as a frequency or torque command source; however, the two cannot function
simultaneously. Throughout this manual they will be listed as
VI/II
.
RX
— Displays the
RX
input setting as a percentage of the full range of the
RX
value (-10 to
+10 VDC input).
RX2
— Displays the
RX2
input setting as a percentage of the full range of the
RX2
value.
Note:
The RX2 function is available on the
ASD-Multicom
option board only.
FM
—
Displays the output frequency value as a percentage of the full range of the
FM
value.
AM
— Displays the output current as a percentage of the full range of the
AM
value.
Option Type
— Displays the type form number of the installed
ASD-Multicom
option board.
Option Term A
— Not Used.
Option Term B
— Not Used.
Option Term O
— Not Used.
Option Term P
— Not Used.
Max. Output
— Not Used.
Pattern Select
— Active Group Number and Speed Number separated by a period (e.g., 2.3).
Repeats Left
— Number of remaining Speed cycles in the active Group.
Pattern
— Active Speed Number of the Group.
Pattern Time Left
— Time remaining in the active Speed.
Summary of Contents for HX7+ ASD
Page 2: ...DN 67017 001 February 2014 HX7 ASD Installation Operation Manual ...
Page 227: ...218 HX7 ASD Installation and Operation Manual Figure 35 200 kVA Sine Wave NEMA 1 Enclosure ...
Page 231: ...222 HX7 ASD Installation and Operation Manual Figure 39 200 kVA Sine Wave NEMA 3R Enclosure ...
Page 235: ...226 HX7 ASD Installation and Operation Manual Figure 43 66 163 kVA 18 Pulse Enclosure ...
Page 236: ...HX7 ASD Installation and Operation Manual 227 Figure 44 200 kVA 18 Pulse Enclosure ...
Page 237: ...228 HX7 ASD Installation and Operation Manual Figure 45 260 518 kVA 18 Pulse Enclosure ...
Page 238: ...HX7 ASD Installation and Operation Manual 229 Figure 46 518 700 kVA 18 Pulse Enclosure ...