132
HX7+ ASD Installation and Operation Manual
Light-Load High-Speed Operation Load Wait Time
Program
Special Control
Crane/Hoist Load
times out, this parameter determines the length of
time that the
Light-Load High-Speed
criteria must be met until the
Light-
Load High-Speed
function engages.
Direct Access Number — F332
Parameter Type —
Numerical
Factory Default —
1.0
Changeable During Run —
Yes
Minimum — 0.0
Maximum — 10.0
Units — Seconds
Light-Load High-Speed Operation Load Detection Time
Program
Special Control
Crane/Hoist Load
This parameter determines the length of time that the load requirement must
meet the
Light-Load High-Speed
criteria before the
Light-Load High-Speed
Enable
) is recognized.
Once recognized, the timer setting of
must expire to engage the
Light-
Load High-Speed
function.
Direct Access Number — F333
Parameter Type —
Yes
Factory Default —
1.0
Changeable During Run —
Numerical
Minimum — 0.0
Maximum — 10.0
Units — Seconds
Light-Load High-Speed Operation Heavy-Load Detection
Time
Program
Special Control
Crane/Hoist Load
While operating in the
Light-Load High-Speed
mode, this parameter
determines the length of time that a load exceeding the
Light-Load High-
Speed
operation criteria may exist before the
Light-Load High-Speed
mode is
terminated and normal operation resumes.
Direct Access Number — F334
Parameter Type —
Numerical
Factory Default —
5.0
Changeable During Run —
Yes
Minimum — 0.0
Maximum — 10.0
Units — Seconds
Switching Load Torque During Forward Run
Program
Special Control
Crane/Hoist Load
While running forward, this parameter establishes the threshold torque level
that is used to determine if the
Light-Load High-Speed
) operation may
engage or remain engaged if active.
If the
Light-Load High-Speed
operation is terminated, normal operation
resumes.
Direct Access Number — F335
Parameter Type —
Numerical
Factory Default —
50
Changeable During Run —
No
Minimum — 0
Maximum — 250
Units — %
Heavy-Load Torque During Forward Acceleration
Program
Special Control
Crane/Hoist Load
During forward acceleration, this parameter establishes the threshold torque
level that is used to determine if the
Light-Load High-Speed
(
) operation
may engage or remain engaged if active.
If the
Light-Load High-Speed
operation is terminated, normal operation
resumes.
Direct Access Number — F336
Parameter Type —
Numerical
Factory Default —
150
Changeable During Run —
Yes
Minimum — 0
Maximum — 250
Units — %
Heavy-Load Torque During Fixed Speed Forward Run
Program
Special Control
Crane/Hoist Load
While running forward at a fixed speed, this parameter establishes the threshold
torque level that is used to determine if the
Light-Load High-Speed
(
)
operation may engage or remain engaged if active.
If the
Light-Load High-Speed
operation is terminated, normal operation
resumes.
Direct Access Number — F337
Parameter Type —
Numerical
Factory Default —
100
Changeable During Run —
Yes
Minimum — 0
Maximum — 250
Units — %
Summary of Contents for HX7+ ASD
Page 2: ...DN 67017 001 February 2014 HX7 ASD Installation Operation Manual ...
Page 227: ...218 HX7 ASD Installation and Operation Manual Figure 35 200 kVA Sine Wave NEMA 1 Enclosure ...
Page 231: ...222 HX7 ASD Installation and Operation Manual Figure 39 200 kVA Sine Wave NEMA 3R Enclosure ...
Page 235: ...226 HX7 ASD Installation and Operation Manual Figure 43 66 163 kVA 18 Pulse Enclosure ...
Page 236: ...HX7 ASD Installation and Operation Manual 227 Figure 44 200 kVA 18 Pulse Enclosure ...
Page 237: ...228 HX7 ASD Installation and Operation Manual Figure 45 260 518 kVA 18 Pulse Enclosure ...