HX7+ ASD Installation and Operation Manual
185
RS232/RS485 Communications Time-Out Action
Program
Communication
Communication Settings
This parameter plays a role in the setup of the communications network by
determining the action to be taken in the event of a time-out (
Time-Out
Action
).
The communications network includes other ASDs and Host/Control computers
that monitor the status of the ASD(s), transfers commands, and loads or
modifies the parameter settings of the drive.
Changes made to this parameter require that the power be cycled (Off then On)
for the changes to take effect.
Settings:
0 — No Action
1 — Alarm
2 — Trip
Direct Access Number — F804
Parameter Type —
Selection List
Factory Default —
Trip
Changeable During Run —
Yes
Communication Interval
Program
Communication
Communication Settings
This parameter sets the
Common Serial
response delay time.
Changes made to this parameter require that the power be cycled (Off then On)
for the changes to take effect.
Direct Access Number — F805
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — 0.00
Maximum — 2.00
Units — Seconds
TTL Master Output
Program
Communication
Communication Settings
In a master/follower configuration, this setting determines the output parameter
of the master ASD that will be used to control the applicable follower ASDs.
Note:
Select
No Follower
is configured as a
Master Output
controller. Otherwise, a keypad failure will result.
Changes made to this parameter require that the power be cycled (Off then On)
for the changes to take effect.
Settings:
0 — No Follower (normal operation)
1 — Frequency Reference
2 — Output Command Frequency
3 — Torque Command
4 — Output Torque Command
Direct Access Number — F806
Parameter Type —
Selection List
Factory Default —
No Follower
(normal
operation)
Changeable During Run —
Yes
Summary of Contents for HX7+ ASD
Page 2: ...DN 67017 001 February 2014 HX7 ASD Installation Operation Manual ...
Page 227: ...218 HX7 ASD Installation and Operation Manual Figure 35 200 kVA Sine Wave NEMA 1 Enclosure ...
Page 231: ...222 HX7 ASD Installation and Operation Manual Figure 39 200 kVA Sine Wave NEMA 3R Enclosure ...
Page 235: ...226 HX7 ASD Installation and Operation Manual Figure 43 66 163 kVA 18 Pulse Enclosure ...
Page 236: ...HX7 ASD Installation and Operation Manual 227 Figure 44 200 kVA 18 Pulse Enclosure ...
Page 237: ...228 HX7 ASD Installation and Operation Manual Figure 45 260 518 kVA 18 Pulse Enclosure ...
Page 238: ...HX7 ASD Installation and Operation Manual 229 Figure 46 518 700 kVA 18 Pulse Enclosure ...