176
HX7+ ASD Installation and Operation Manual
Acceleration Time Adjustment
Program
Terminal Selection
Analog In Functions
This parameter
Enables/Disables
the feature that allows for the external
adjustment of the
Acceleration Time
. Selecting either
VI/II
or
RR
enables this
feature. The selected input is used as a multiplier of the programmed
Acceleration Time
setting. The multiplication factor may be from 1 to 10.
Note:
An acceleration time shorter than the load will allow may cause
nuisance tripping and mechanical stress to loads.
Settings:
0 — Disabled
1 — VI/II
2 — RR
Direct Access Number — F652
Parameter Type —
Selection List
Factory Default —
Disabled
Changeable During Run —
Yes
Deceleration Time Adjustment
Program
Terminal Selection
Analog In Functions
This parameter
Enables/Disables
the feature that allows for the external
adjustment of the
Deceleration Time
. Selecting either
VI/II
or
RR
enables this
feature. The selected input is used as a modifier of the programmed
Deceleration Time
setting.
Note:
A deceleration time shorter than the load will allow may cause
nuisance tripping and mechanical stress to loads.
Settings:
0 — Disabled
1 — VI/II
2 — RR
Direct Access Number — F653
Parameter Type —
Selection List
Factory Default —
Disabled
Changeable During Run —
Yes
Torque Boost Adjustment
Program
Terminal Selection
Analog In Functions
This parameter
Enables/Disables
the feature that allows for the external
adjustment of the
Torque Boost
setting. Selecting either
VI/II
or
RR
enables
this feature. The selected input is used as a modifier of the programmed
Torque
Boost
setting.
Settings:
0 — Disabled
1 — VI/II
2 — RR
Direct Access Number — F654
Parameter Type —
Selection List
Factory Default —
Disabled
Changeable During Run —
Yes
Summary of Contents for HX7+ ASD
Page 2: ...DN 67017 001 February 2014 HX7 ASD Installation Operation Manual ...
Page 227: ...218 HX7 ASD Installation and Operation Manual Figure 35 200 kVA Sine Wave NEMA 1 Enclosure ...
Page 231: ...222 HX7 ASD Installation and Operation Manual Figure 39 200 kVA Sine Wave NEMA 3R Enclosure ...
Page 235: ...226 HX7 ASD Installation and Operation Manual Figure 43 66 163 kVA 18 Pulse Enclosure ...
Page 236: ...HX7 ASD Installation and Operation Manual 227 Figure 44 200 kVA 18 Pulse Enclosure ...
Page 237: ...228 HX7 ASD Installation and Operation Manual Figure 45 260 518 kVA 18 Pulse Enclosure ...
Page 238: ...HX7 ASD Installation and Operation Manual 229 Figure 46 518 700 kVA 18 Pulse Enclosure ...