HX7+ ASD Installation and Operation Manual
193
shows the output selections for the
AM
,
FM
,
FP
, and
Analog 1
&
2
terminals. The magnitude
of the
AM
and
FM
output signals at full-scale is selection-specific and may be adjusted (see
and
) to fit application-specific requirements.
The column on the right side of
shows the actual
AM
and
FM
outputs for a keypad display of
100%.
Table 15. Output terminal selections for the AM, FM, FP, and Analog 1 & 2 terminals.
Function
AM/FM Output Value at 100%
Keypad-Displayed Output
Output Frequency (
FM
and
FP
default setting)
Maximum Frequency
Frequency Reference
Output Current (
AM
default setting)
150%
DC Bus Voltage
Output Voltage (
Analog 1
default setting)
Post-compensation Frequency (
Analog 2
default setting)
Maximum Frequency
Speed Feedback (realtime)
Speed Feedback (1 sec filter)
Torque
150%
Torque Command
Internal Torque Base
Torque Current
Excitation Current
PID Feedback Value
Maximum Frequency
Motor Overload Ratio
Motor Overload Trip-Point Setting
ASD Overload Ratio
ASD Overload Trip-Point Setting
PBR (DBR) Overload Ratio
DBR Overload Trip Point Setting
PBR (DBR) Load Ratio
Maximum DBR Duty Cycle
Input Power
1.73 * input voltage * ASD rated current
Output Power
Peak Output Current
150%
Peak DC Bus Voltage
PG Counter
32767 Encoder Pulses
Position Pulse
RR Input
100%
VI/II Input
RX Input
RX2 Input
FM Output (used for factory testing only)
AM Output (used for factory testing only)
Meter Adjust Value
Analog Output
Load Torque
150%
Summary of Contents for HX7+ ASD
Page 2: ...DN 67017 001 February 2014 HX7 ASD Installation Operation Manual ...
Page 227: ...218 HX7 ASD Installation and Operation Manual Figure 35 200 kVA Sine Wave NEMA 1 Enclosure ...
Page 231: ...222 HX7 ASD Installation and Operation Manual Figure 39 200 kVA Sine Wave NEMA 3R Enclosure ...
Page 235: ...226 HX7 ASD Installation and Operation Manual Figure 43 66 163 kVA 18 Pulse Enclosure ...
Page 236: ...HX7 ASD Installation and Operation Manual 227 Figure 44 200 kVA 18 Pulse Enclosure ...
Page 237: ...228 HX7 ASD Installation and Operation Manual Figure 45 260 518 kVA 18 Pulse Enclosure ...
Page 238: ...HX7 ASD Installation and Operation Manual 229 Figure 46 518 700 kVA 18 Pulse Enclosure ...