6 - 62
Installing SV9100 Optional Equipment
12.2 Connector Pin-Outs on COIU Blade for Power Failure Circuits
12.3 Installing the Power Failure Telephones
1.
Connect an RJ-61 connector to the COIU Blade installed in the system.
2.
Install a modular jack for each single line telephone supporting PF
operation. The modular jack should be within six feet of the phone.
3.
For each extension, run one-pair 24 AWG station cable from the cross-
connect block to a modular jack.
4.
Terminate the extension leads to GRN/RED of the modular jack.
Terminate the unused leads to the jack. Refer to
Figure 6-64 Power
Failure Connector (CN3) Shown on GCD-4COTA Blade on page 6-63
.
Table 6-4 RJ-61 Cable Connector
RJ-61 Cable Connector - CN13, SLT Interface for Power Failure
Pin No.
Connection
1
–
2
–
3
Circuit 2 - Tip
4
Circuit 1 - Ring
5
Circuit 1 - Tip
6
Circuit 2 - Ring
7
–
8
–
When connecting the RJ-61 cables to the COIU Blade,
note the position of the Power Failure connector. Do not
confuse connector CN3 as the CN2 trunk connector.
Summary of Contents for Univerge SV9100
Page 1: ...System Hardware Manual Issue 1 2 January 2015...
Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 40: ...Issue 1 2 UNIVERGE SV9100 1 16 Introduction to SV9100...
Page 105: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 3 33 Figure 3 42 Brackets Small Batt Box...
Page 154: ...Issue 1 2 UNIVERGE SV9100 3 82 Installing the SV9100 Chassis...
Page 239: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 4 85 Figure 4 24 Control Signal Connection...
Page 259: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 4 105 NOTES...
Page 260: ...Issue 1 2 UNIVERGE SV9100 4 106 Installing the SV9100 Blades...
Page 412: ...Issue 1 2 UNIVERGE SV9100 5 152 Installing DT Series Digital and IP Multiline Terminals...
Page 476: ...Issue 1 2 UNIVERGE SV9100 6 64 Installing SV9100 Optional Equipment...