UNIVERGE SV9100
Issue 1.2
System Hardware Manual
3 - 81
5.
Remove cabling from retention clips.
6.
Remove two screws securing fan to access cover. Keep screws for
use when installing replacement fan.
8.1.2
Install Cooling Fan
1.
Align replacement fan with holes and secure with two screws.
2.
Install cabling into retention clips.
3.
Insert access panel hinges into slots on rear of chassis.
4.
Plug fan power cable into three prong plug.
5.
Reinstall access cover and secure with retaining screw.
Figure 3-114 Chassis Access Panel Removed (19” Chassis)