Summary of Contents for ElectraElite IPK

Page 1: ...may occur causing slight variations When viewing and printing this document we cannot guarantee that your specific PC or printer will support all of the fonts or graphics Therefore when you view the d...

Page 2: ...GENERAL DESCRIPTION MANUAL INT 1024 IPK Document Revision 4 Release 4000 4500...

Page 3: ......

Page 4: ...ut prior written approval of NEC Unified Solutions Inc Dterm and NEAX are registered trademarks of NEC Corporation and Electra Elite and EliteMail are registered trademarks of NEC America Inc TeLANoph...

Page 5: ......

Page 6: ...ry to install and support the system The manuals are described in this preface THIS MANUAL This manual provides general information about the system its features system configuration and standards Thi...

Page 7: ...ra Elite IPK Least Cost Routing Manual This manual provides instructions to the service technician for programming the customer site for least cost routing Electra Elite IPK Job Specifications Manual...

Page 8: ...Regulatory Information...

Page 9: ...h changes affect the compatibility or use of the Electra Elite IPK system the telephone company is required to give adequate notice of the changes COMPANY NOTIFICATION Before connecting this telephone...

Page 10: ...ephone company may temporarily disconnect service Table 1 FIC REN SOC and Jack Types for Electra Elite IPK System ETUs Trunk Station ETU Type FIC REN SOC Jack BRT 4 U ETU 02IS5 N A 6 0F N A CAMA Trunk...

Page 11: ...cause interference in which case the user at his or her own expense is required to take whatever measures may be required to correct the interference When equipped with the B64 U30 KSU and P64 U20 PS...

Page 12: ...ctice to monitor or record a telephone conversation Some federal and state laws require a party monitoring or recording a telephone to use a beep tone s notify all parties to the telephone conversatio...

Page 13: ...tion of this telephone system to or from the telephone network the telephone company must be provided with the following information 1 Your telephone number 2 IC registration number 140 7942 A 3 Ringe...

Page 14: ...the sum of the Ringer Equivalent Numbers of all the devices does not exceed five This equipment has been listed by the Canadian Standards Association and found to comply with all applicable requiremen...

Page 15: ...Contact your local solid waste management officials for other information regarding the environmentally sound collection recycling and disposal of the battery Nickel Cadmium or sealed lead batteries m...

Page 16: ..._______________ PRODUCT PACKAGE LABELING CONTAINS NICKEL CADMIUM BATTERY BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY MUST NOT BE DISPOSED OF IN MUNICIPAL WASTE CONTAINS SEALED LEAD BATTERY BATTER...

Page 17: ...1 1 Section 2 Multiline Telephones 1 3 Section 3 System Description 1 9 Chapter 2 Features Section 1 Features List 2 1 Section 2 Features Descriptions 2 5 Chapter 3 Equipment Section 1 Equipment List...

Page 18: ...pply Consumption 5 6 Section 5 Environmental Conditions 5 6 5 1 Temperature 5 6 5 2 Humidity 5 6 5 3 Weights and Dimensions 5 7 Section 6 Audible and Visual Indication 5 12 6 1 Tone Patterns 5 12 6 2...

Page 19: ...________________________________________________________________________________ Section 10 External Equipment Connection 5 18 10 1 Music Sources for Music on Hold via KSU 5 18 10 2 Music Source for S...

Page 20: ...te IPK ___________________________________________________________________________________ iv Table of Contents ___________________________________________________________________________________ THIS...

Page 21: ...ingle Line Telephones 1 18 Figure 1 7 Attendant Consoles 1 19 Figure 1 8 Dterm Cordless Lite Terminal 1 19 Figure 1 9 Dterm Cordless II Terminal 1 20 Figure 1 10 Dterm Cordless Lite II Terminal 1 21 F...

Page 22: ...ite IPK ___________________________________________________________________________________ vi List of Figures ___________________________________________________________________________________ THIS...

Page 23: ...ased ETU Quantity Limitations for Systems without EliteMail VP CTI or CTI ETU loaded with Q Master application 3 19 Table 3 5 KSU Power Based ETU Quantity Limitations for Systems with EliteMail VP CTI...

Page 24: ...ite IPK ___________________________________________________________________________________ viii List of Tables ___________________________________________________________________________________ THIS...

Page 25: ...Chapter 1 Introduction...

Page 26: ...es This system provides Windows 95 98 Windows ME Windows 2000 and Windows XP based PC programming with a menu driven guide to both simplify and speed installation All programming information and stati...

Page 27: ...users make calls Voice Mail integration Automated Attendant and personalized messaging all give the system that personal touch so important in a well run business Most communication equipment can be c...

Page 28: ...H Universal Slots H Voice over Internet Protocol VoIP and stations H Wireless H IP Telephony H Optional 33 6 kbps Modem for Remote Programming and Maintenance SECTION 2 MULTILINE TELEPHONES The Elect...

Page 29: ...R CT A R Unit and CT U R Unit adapters The AP R R Unit requires an AC R Unit to supply AC power An Attendant Add On DCR 60 1 CONSOLE is available with 60 station outside line and or function key assi...

Page 30: ...s from none to 16 depending on the terminal type J Dterm Series i Terminals The Dterm Series i Terminals DTR telephones offer a variety of colors display and non display types and line sizes Terminals...

Page 31: ...with a Message Waiting Indicator that also functions as an Incoming Call Indication During a call the receive audio level can be increased three levels and decreased two levels from the default settin...

Page 32: ..._____________________ ___________________________________________________________________________________ An Attendant Add On DCR 60 1 CONSOLE is available with 60 station outside line and or function...

Page 33: ...ne External Speakerphone Headset Attendant Console Dterm Cordless Lite CO PBX Centrex DID Tie FT1 ISDN BRI ISDN PRI Least Cost Routing Electra Elite Multiline Terminal DTU Dterm Series E Multiline Ter...

Page 34: ...CTI or CTI ETU loaded with Q Master application on page 3 19 and Table 3 5 KSU Power Based ETU Quantity Limitations for Systems with EliteMail VP CTI or CTI ETU loaded with Q Master Application on pa...

Page 35: ...side lines and other devices or features The same ETUs are used for both the basic and expanded port packages The universal slot design minimizes the hardware required for a system and provides greate...

Page 36: ...line terminal without display DTR 8 1 TEL H 8 line terminal with display DTR 8D 1 TEL H 16 line terminal without display DTR 16 1 TEL H 16 line terminal with display DTR 16D 1 TEL H 16 line terminal w...

Page 37: ...ompatible with AD A R AP A R AP R R or CT A R Unit adapters DTP DTU terminals except for DTP 2DT 1 and DTP 16HC 1 or cordless terminals are compatible with ADA U APA U APR U CTA U CTU S U or HFU U DTP...

Page 38: ...products Refer to Figure 1 4 Elite IPK DTH ITH Dterm Series i DTR Multiline Terminals Figure 1 5 Electra Elite Multiline Terminals Figure 1 6 DTR Single Line Telephones Figure 1 7 Attendant Consoles...

Page 39: ...______________ Document Revision 4 Electra Elite IPK Figure 1 4 Elite IPK DTH ITH Dterm Series i DTR Multiline Terminals DTH 8 1 TEL DTR 8 1 TEL 8 Line Non display DTH 8D 1 ITH 8D 2 3 DTR 8D 1 TEL 8 L...

Page 40: ...___________________________________ ___________________________________________________________________________________ Figure 1 4 Elite IPK DTH ITH Dterm Series i DTR Multiline Terminals continued DT...

Page 41: ...______ ___________________________________________________________________________________ Document Revision 4 Electra Elite IPK Figure 1 5 Electra Elite Multiline Terminals DTU 8 1 TEL 8 Line Non dis...

Page 42: ...________________________ ___________________________________________________________________________________ Figure 1 5 Electra Elite Multiline Terminals continued DTU 32 1 TEL 16 Line Non display wit...

Page 43: ..._________________________________________________________ ___________________________________________________________________________________ Document Revision 4 Electra Elite IPK Figure 1 6 DTR Singl...

Page 44: ...__________________________________________________ ___________________________________________________________________________________ Figure 1 7 Attendant Consoles DCR 60 1 Console Dterm Series i Ele...

Page 45: ...________________________________________________________________ ___________________________________________________________________________________ Document Revision 4 Electra Elite IPK Figure 1 9 Dt...

Page 46: ...______________________________________________ Figure 1 10 Dterm Cordless Lite II Terminal DTH 4R 1 Handset Dterm Cordless Lite II Terminal Controls 1 Headset Jack 5 Numeric Key Pad 9 CONF Conference...

Page 47: ...________________ ___________________________________________________________________________________ Document Revision 4 Electra Elite IPK Figure 1 11 Dterm Cordless Lite II Base Unit 20 19 21 22 23 1...

Page 48: ...nual 1 23 ___________________________________________________________________________________ ___________________________________________________________________________________ Figure 1 12 Dterm Hand...

Page 49: ..._____________________________________________________________________________ ___________________________________________________________________________________ Document Revision 4 Electra Elite IPK...

Page 50: ...1 25 ___________________________________________________________________________________ ___________________________________________________________________________________ Figure 1 15 Dterm Analog C...

Page 51: ...____________________________ ___________________________________________________________________________________ Document Revision 4 Electra Elite IPK Figure 1 17 Zone Transceiver ZT II Figure 1 18 DB...

Page 52: ...cription Manual 1 27 ___________________________________________________________________________________ ___________________________________________________________________________________ Figure 1 19...

Page 53: ...________________________________________________________________________ ___________________________________________________________________________________ Document Revision 4 Electra Elite IPK THIS...

Page 54: ...Chapter 2 Features...

Page 55: ...log EXT B A 7 Ancillary Device Connection B 1 Background Music Over External Speakers A 8 Answer Hold B 2 Background Music Multiline Speaker A 9 Answer Key B 3 Barge In A 10 Assigned Night Answer B 4...

Page 56: ...ction E 2 Electra Elite IPK Terminals C 23 CO Message Waiting Indication E 3 Electra Elite IPK Terminal Migration C 24 Computer Telephony Integration E 4 Electra Professional Terminal Migration C 25 C...

Page 57: ...t In M 7 Music on Hold H 5 Hold With Recall Exclusive and Non Exclusive N H 6 Hot Key Pad N 1 NEC Elite PC Assistant H 7 Hot Line N 2 Nesting Dial H8 Howler Tone Service N 3 Night Call Pickup I N 4 Ni...

Page 58: ...Trunk Queuing S 1 Save and Repeat T 7 Trunk to Trunk Transfer S 2 Scrolling Directories T 8 Two Color LEDs S 3 Secondary Incoming Extension U S 4 Seized Trunk Name Number Display U 1 Unified Messagin...

Page 59: ...ion users to dial an Access Code and an unverified Account Code before making an outgoing call The outgoing call is processed only after the unverified Account Code is dialed This feature allows a sys...

Page 60: ...n appearance from the office KTS When 5 6 or 7 digit station numbers are used R2000 or higher this feature is unavailable A 7 ANCILLARY DEVICE CONNECTION Ancillary Device Connection allows installatio...

Page 61: ...ess to a maximum of 48 stations and or outside lines The Busy Lamp Field status is shown by a red LED for each station or trunk Trunks can include CO PBX ISDN DID E M Tie Lines and FT1 lines The Atten...

Page 62: ...zation Code is dialed the station code restriction class temporarily changes to allow calls when permitted by a new code restriction class The Authorization Code can be verified or unverified based on...

Page 63: ...500 or higher has been added that provides real time queue and agent information to the agent desktop and serves as a cost effective alternative to expensive wall displays Text messages can be sent to...

Page 64: ...Redial simplifies repetitive dialing to a busy or unanswered outgoing call After a busy tone or no answer is received during a CO PBX call the system periodically redials the party number while the st...

Page 65: ...76 Barge In Alert Tone Assignment controls the Conf LED to light or not light at the station barged into Prior to this the Conf LED was always on at the barged into station B 4 BATTERY BACKUP SYSTEM...

Page 66: ...are received and a limited number of CO line key appearances are available These keys are often called CO loop keys C 3 CALL ARRIVAL KEYS Call Arrival CAR keys are available software extensions as pa...

Page 67: ...t 50 incoming calls by using the Caller ID Scroll key when assigned MIFM U firmware V5 00 is required for 50 Caller ID scroll buffers With lower level firmware 10 Caller ID scroll buffers are provided...

Page 68: ...d to one station to another station Voice Mail system or to the Attendant Position for Busy or Ring No Answer This permits more efficient call processing by allowing calls to be routed to another stat...

Page 69: ...istration Terminal SAT software allows Call Forward settings to be assigned and saved as part of the site database C 13 CALL MONITORING This feature allows selected Multiline Terminal users to monitor...

Page 70: ...the same as an Electra Elite IPK linked to another Electra Elite IPK using K CCIS R1700 or higher is required C 18 CENTRALIZED VOICE MAIL With E M TIE LINES Centralized Voice Mail allows two or more s...

Page 71: ...nk appearance R2000 or higher is required C 24 COMPUTER TELEPHONY INTEGRATION CTI integrates computers and telephones to allow access of sophisticated communication services using telephone lines The...

Page 72: ...lso supports cordless telephones but this feature refers to Multiline Terminal cordless connection C 27 CUSTOMIZED MESSAGE A station with Do Not Disturb set can select a Customized Message that is dis...

Page 73: ...inserts the PBX Centrex Trunk Access Code The user does not have to dial an Access Code D 7 DIGITAL LINE EXTENDER Dterm EXTENDER PLUS Dterm ISDN EXTender Plus allows a user with an NEC Multiline Tele...

Page 74: ...sfully entering a password D 11 DIRECT INWARD TERMINATION Direct Inward Termination DIT allows CO PBX lines to be programmed to bypass the Attendant and ring directly at stations or tenants A separate...

Page 75: ...swers the doorphone ringing a 2 way speech path is established Both the tone and cadence of doorphone ringing can be defined to allow the station user to distinguish a doorphone call from any other ca...

Page 76: ...The system allows users at branch offices or telecommuters to take advantage of the rich feature set of the company central site Key Telephone System as though they were connected locally without los...

Page 77: ...rminals when purchasing Electra Elite IPK systems With very few exceptions all terminal features and abilities that are possible on Electra Professional Level II IIA 120 are also possible with the Ele...

Page 78: ...ewed based on the DNIS number and name E 8 ELITE CALLANALYST Elite CallAnalyst is an easy to use graphically oriented software package that allows a user to monitor and analyze telephone calls underst...

Page 79: ...APPS PC ATTENDANT This feature allows easy access to the most common functions required by an operator or receptionist Using this application the attendant can manage call handling without having to s...

Page 80: ...ation permits Speed Dial memories and Code Restriction to be applied to CO PBX lines that provide access to a Specialized Common Carrier SCC E 15 EXTERNAL TONE RINGER The External Tone Ringer provides...

Page 81: ...tensions can also be assigned to Flexible Line keys With R2000 or higher Digital Voice Mail integrated functions can be assigned to Line Keys that are assigned as Feature Access Keys on a multiline Te...

Page 82: ...UND START TRUNKS Ground Start Trunks can be connected to the system Assignment of trunks as Ground Start is per trunk by switch settings at the associated COI 8 U or COIB 4 U10 ETU Ground and Loop Sta...

Page 83: ...n Exclusive Hold A call on hold for longer than a preprogrammed interval generates a recall at the originating station When the recalled Multiline Terminal is idle an audible signal and an LCD indicat...

Page 84: ...ergence point where data arrives from one or more directions and is forwarded out in one or more other directions A hub usually includes a switch a switch could usually be considered a hub as well Dat...

Page 85: ...EGACO The IAD 8 U ETU is an optional interface for Electra Elite IPK that converts digital station ports to MEGACO IP station ports An onboard 10 100 Base T connector provides a WAN LAN connection Voi...

Page 86: ...I a Common Channel Handler CCH for receiving or transmitting common signaling data from to a distant office and a CLKG U Unit for network synchronization The system can provide a variety of interoffic...

Page 87: ...Central Office number dialed Call costs are minimized by automatically selecting the least expensive available connection for outgoing calls With R3000 or higher LCR can be used with the MIFM U20 ETU...

Page 88: ...one Control allows ON OFF status indication on all Multiline Terminals A Flexible Line key or One Touch key programmed for Microphone Control or an Access Code is used to mute the microphone for priva...

Page 89: ...n Speed Dial numbers in one Station Speed Dial buffer The user can press the Redial key and dial a single Station Speed Dial buffer number to consecutively dial all four buffers System software permit...

Page 90: ...on Speed Dial without going off hook first P 1 PC PROGRAMMING The MIFM U ETU and System Administration Terminal SAT software allow the system to be programmed from a personal computer PC System Data i...

Page 91: ...user to go off hook and originate an outside call from the trunk assigned as the Prime Line without pressing the line key This feature allows assignment of a trunk Trunk group or Route Advance Block P...

Page 92: ...ll while retaining the CO PBX line for another call Each Multiline Terminal has a Recall key The function of this key is programmed R 2 RECALL WITH STATION IDENTIFICATION A transferred held or camped...

Page 93: ...Advance Block assigns up to 32 tables Each table can contain four Trunk group priority levels from lowest cost to most expensive Station users may have a Route Advance key programmed on their telepho...

Page 94: ...provides the same functions as the MIFM U10 with the KMM U PAL chip installed or the MIFM U20 with the KMM U20 upgrade chip installed and comes with a standard built in modem An Ethernet port is provi...

Page 95: ...d action S 10 SOFTKEYS The Electra Elite IPK system provides softkeys on all display Electra Elite IPK DTH ITH Dterm Series i DTR Electra Elite DTU or Dterm Series E DTP Multiline Terminals Currently...

Page 96: ...fers System Software permits input stored characters to be entered on the dial pad but does not allow the Character Code Table to be used With R4000 or higher an additional 10 Station Speed Dials are...

Page 97: ...e allows a user to program a 16 character Station Name for telephone extensions and allows the Attendant Station user to program any extension in the system R4000 or higher S 19 STATION OUTGOING LOCKO...

Page 98: ...lectra Elite IPK System Administration Terminal SAT Software transfers Station Speed Dial data System Speed Dial data and all System Data from to an NEC PowerMate or Pentium1 compatible PC System Data...

Page 99: ...ecting the specific trunk in the queue procedure This feature allows a station user to set trunk queuing to the specified trunk internal Trunk group or Route Advance Block T 7 TRUNK TO TRUNK TRANSFER...

Page 100: ...l UCD stations busy or no answer the call is queued and the caller receives a Delay Announcement after a programmed time When 5 6 or 7 digit station numbers are used this feature is unavailable U 4 UN...

Page 101: ...ility a message can be sent to the station indicating a Voice Mail Message was received The two packages can support a maximum of 16 ports for Analog Voice Mail when Digital Voice Mail integration or...

Page 102: ...s voice guidance for assisting station users The voice prompt replaces the call waiting tone and or internal dial tone A VRS 4 U ETU must be installed W 1 WIRELESS Using a Personal Station Dterm PS II...

Page 103: ...Chapter 3 Equipment...

Page 104: ...in the Electra Elite IPK system are shown in Table 3 1 Maximum System Capacities for Station Interface ETUs Table 3 2 Maximum System Capacities for Trunk Interface ETUs and Table 3 3 Maximum System C...

Page 105: ...station ports in the system 2 2 Notes 1 8 9 CTI 12 16 U ETU Daughter Board This ETU and the 4 and 8 port ETU provide a 12 or 16 port Digital Voice Mail system with ports that support TeLANophy inboun...

Page 106: ...an support any Attendant Console Multiline Terminal or Single Line Telephone adapter This ETU is installed in slots S1 S8 in the basic or expansion B64 U20 KSU The maximum number depends on other stat...

Page 107: ...ce The Off Premise Extension ETU provides termination and operation of two off premise extensions Each ETU has a built in ringer RSG Up to 1600 ohms of loop resistance including the Single Line instru...

Page 108: ...Single Line Telephones This ETU provides Ringing Signal Generator RSG and Message Waiting MW LED voltage to Single Line Telephones This ETU is installed in slots S1 S8 in any KSU The maximum number de...

Page 109: ...stem recognizes this ETU as VMS 8 U ETU This ETU shares the total number of station ports in the system 1 1 Notes 1 4 5 10 VMP 2 4 U ETU 2 or 4 port Digital Voice Mail System This ETU is installed in...

Page 110: ...ard Interface Slot Assignment and as YS VM in Memory Block 4 35 Voice Mail SLT Selection Note 9 A maximum of 16 analog Voice Mail ports are available in Memory Block 4 35 Voice Mail SLT Selection Note...

Page 111: ...supported This ETU is installed in slots S1 S4 in the basic or first expansion B64 U20 KSU The maximum number depends on other trunk cards installed This ETU shares the total number of CO PBX lines in...

Page 112: ...he system 2 8 Note 1 COIB 4 U ETU 4 port COI or COID CO PBX Line Interface This ETU can function the same as the COI 4 U or COID 4 U ETU to provide Central Office interface When ETU is set for COID mo...

Page 113: ...MA trunk on port 3 or 7 The maximum number depends on other Trunk cards installed This ETU shares the total number of CO PBX lines in the system Tip and Ring electrical fuses are provided to comply wi...

Page 114: ...c Number Indication ANI is supported Only the DTI U30 ETU supports K CCIS common channel signaling A combination of Loop Start and Ground Start trunks DID trunks or Tie lines can be used on the ETU Ea...

Page 115: ...ture Group D incoming MF outgoing DTMF signaling is also supported This ETU also supports K CCIS signaling with point to point E M Tie Lines This ETU is installed in any slot in the basic or expansion...

Page 116: ...n other trunk cards installed This ETU shares the total number of CO PBX lines in the system This ETU shares the total number of station ports in the system 4 15 Note 1 5 IPT 8 U ETU 8 port Voice over...

Page 117: ...U ETU installed as COID 4 U ETU H DTI U ETU installed as DTI4 H IPT 4 U ETU installed as COID 4 U ETU or DTI4 PRT 1 U ETU ISDN Primary Rate Trunk Interface The Integrated Service Digital network ISDN...

Page 118: ...ed 8 8 BSU 4M U20 ETU 4 Channel Base Station Unit Master for Wireless DECT with connection for up to 16 Base Stations when using two BSU 6S ETUs This ETU is installed in slots S1 S8 S2 S8 when using o...

Page 119: ...stalled in slots S1 S8 in the basic B64 U20 KSU 1 1 HUB 8 U ETU This ETU is an optional Ethernet Interface that supports eight Ethernet ports Each port has two LEDs that indicate status and activity O...

Page 120: ...onal memory for PC programming SMDR LCR Caller ID scrolling and Wireless programming When the LCR or Caller ID Scroll functions are desired the KMM 1 0 U must be installed 1 1 Note 1 2 MIFM U20 ETU Mu...

Page 121: ...st B64 U20 KSU Note 4 R1500 or higher is required Note 5 R3000 or higher is required Note 6 R4000 R4500 only Note 7 A maximum of one BSU M Master and two BSU 2S 6S Slave ETUs can be installed SPE M U...

Page 122: ...ETU loaded with Q Master application Number of ESI 8 ETUs Number of ESI Ports Either EliteMail VP CTI Maximum NO of ACD CMS FMS VMS VMP IPC MG IVR IPT IAD SLI OPX BSU 4M BSU 2S BSU 6S or DID ETUs Oth...

Page 123: ...aximum NO of ACD CMS FMS VMS VMP IPC MG IVR IPT IAD SLI OPX BSU 4M BSU 2S BSU 6S or DID ETUs Other ETUs 9 72 1 0 No Limitation 8 64 1 0 No Limitation 7 56 1 1 No Limitation 6 48 1 2 No Limitation 5 40...

Page 124: ...Chapter 4 Installation Programming and Maintenance Overview...

Page 125: ...unit and the battery backup unit are installed in the KSU and allow for easy connection to extra battery backup units All circuits installed in the KSUs are located on printed circuit boards that plug...

Page 126: ...g Multiline Terminals and Single Line Telephones A variety of telephones can be connected to satisfy the requirements of a particular installation All Multiline Terminals are fully modular and are pow...

Page 127: ...l Multiline Terminals without programmable One Touch keys and Single Line Telephones can be used to program Station Speed Dial memories Attendant Positions can be used to program System Speed Dial mem...

Page 128: ...erview ___________________________________________________________________________________ ___________________________________________________________________________________ Document Revision 4 Elect...

Page 129: ...Chapter 5 Hardware Specifications...

Page 130: ...nsion KSUs 1 Basic KSU 8 interface slots 2 Basic KSU Expansion KSU 16 interface slots 3 Basic KSU 2 Expansion KSUs 24 interface slots Some capacities of the Electra Elite IPK system are listed below R...

Page 131: ...ne Terminal Loop Resistance and Cable Length for the loop resistance and cabling requirements for Multiline Terminals and adapters Table 5 1 Dterm Series i or Dterm IP Terminal Loop Resistance and Cab...

Page 132: ...ir Cable 24 AWG DBM B U Box N A 900 900 DCU 60 1 CONSOLE N A 1000 1000 DTU 8 1 TEL DTP 8 1 TEL 35 600 1000 DTU 8D 2 TEL DTP 8D 1 TEL 35 600 1000 DTU 16 1 TEL DTP 16 1 TEL 26 450 900 DTU 16D 2 TEL DTP...

Page 133: ...to Telephone AD A R or AD A 2R Unit Twisted Pair 10 feet ADA 2 W Unit Twisted Pair 10 feet AP A R or AP R R Unit Twisted Pair 50 feet APA U Unit or APR U Unit Twisted Pair 50 feet OPX 2 U ETU Twisted...

Page 134: ...__________________________________________ ___________________________________________________________________________________ Table 5 5 Cabling Requirements for Audio Connected Equipment Cable Music...

Page 135: ...10 H 60 Hz 10 H Single Phase H 7 5A circuit H A dedicated outlet separately fused and grounded is required 4 2 Power Supply Consumption The power consumption for the Electra Elite IPK system is liste...

Page 136: ...it 4 0 oz 113 g 2 25 56 25 mm 2 75 68 75 mm 5 5 137 5 mm AP A R Unit 5 6 oz 158 g 2 25 56 25 mm 2 75 68 75 mm 5 5 137 5 mm AP R R Unit 5 6 oz 158 g 2 25 56 25 mm 2 75 68 75 mm 5 5 137 5 mm APA U Unit...

Page 137: ...U ETU 16 6 oz 471 g 1 97 50 mm 9 45 240 mm 7 68 195 mm COID 4 U ETU 14 4 oz 408 g 1 97 50 mm 9 45 240 mm 7 68 195 mm COID 8 U ETU 16 6 oz 471 g 1 97 50 mm 9 45 240 mm 7 68 195 mm CPUI U ETU 13 4 oz 3...

Page 138: ...32D 1 TEL 48 oz 1361 g 4 78 122 mm 10 2 260 mm 9 8 250 mm DTI U ETU 13 2 oz 374 g 1 89 48 mm 11 47 290 mm 8 46 214 mm DTI U40 ETU 5 99 oz 170 g 1 89 48 mm 11 47 290 mm 8 46 214 mm DTP 1 1 TEL DTP 1 2...

Page 139: ...0 mm ECR U ETU 21 2 oz 344 g 1 97 50 mm 9 45 240 mm 7 68 195 mm ESI 8 U ETU 14 5 oz 411 g 1 97 50 mm 9 45 240 mm 7 68 195 mm ESIB 8 U ETU 11 1 oz 315 g 1 97 50 mm 9 45 240 mm 7 68 195 mm ESIE 8 U ETU...

Page 140: ...195 mm PS A R Unit 7 32 oz 205 g 5 43 138 mm 5 04 128 mm 2 28 58 mm RAK U Unit 320 0z 9072 g 20 507 mm 15 380 mm 8 5 216 mm SLI 4 U ETU 13 0 oz 370 g 1 97 50 mm 9 45 240 mm 7 68 195 mm SLI 8 U ETU 14...

Page 141: ...stem functions such as dial tone busy tone or ringback tone 6 2 Multiline Terminal LED Flash Patterns The Electra Elite IPK system has 2 color LEDs Green is used primarily for I Use conditions and for...

Page 142: ...Dial Tone 350 440 Continuous Internal Ringback Tone 440 480 1 sec On 2 sec Off LCR Dial Tone 440 Continuous Reorder Tone 480 620 120 IPM Service Set Tone 440 Continuous Special Dial Tone 440 240 IPM...

Page 143: ...e ON Red I ON Series i Red ICM I Use ICM Incoming Call Voice Over Broker Red Red Red Large LED Incoming Internal Call Incoming Outside Call Message from Attendant Voice Mail Message Red Green Green Re...

Page 144: ...ks H ISDN PRI Trunks H VoIP Trunks Internet Protocols SECTION 8 NETWORK AND CONTROL 8 1 Transmission Network and Control Specifications 8 1 1 Transmission H Data Length From Multiline Terminal to ESI...

Page 145: ...ocessor H Multiline Terminal IP 32 bit microprocessor H IP Adapter 32 bit microprocessor H Attendant Console 4 bit microprocessor H SLT Adapter 4 bit microprocessor 8 1 4 Telephone The voltage current...

Page 146: ...ra Elite IPK system the following Dial Pulse specifications are used H Pulse Rate 0 0 5 pps 20 1 0 pps H Percent Break 60 1 5 H Interdigit Interval 0 pps 20 pps 770 ms 830 ms 9 2 Dual Tone Multifreque...

Page 147: ...fault 70 ms minimum SECTION 10 EXTERNAL EQUIPMENT CONNECTION 10 1 Music Sources for Music on Hold via KSU H Auxiliary Input 0 6V PPS Signal Level H Input Impedance 600 10 2 Music Source for Station Ba...

Page 148: ...ight 10 6 PC Connection H Female Connector System Output Standard DB 9 straight 10 7 Relay Contact H All Relay Contact Ratings 500 mA 24Vdc SECTION 11 BATTERY BACKUP The Electra Elite IPK system has b...

Page 149: ..._____________________________________________________________________________ ___________________________________________________________________________________ Document Revision 4 Electra Elite IPK...

Page 150: ...GENERAL DESCRIPTION MANUAL NEC Unified Solutions Inc Document Revision 4 Release 4000 4500...

Page 151: ......