![background image](http://html1.mh-extra.com/html/nec/univerge-sv9100/univerge-sv9100_hardware-manual_3936970166.webp)
Issue 1.2
UNIVERGE SV9100
4 - 12
Installing the SV9100 Blades
2.6.3.4
Saving Your Configuration
When programming is completed, to exit out of the program
option and save changes to the GCD-CP10:
1. Press
EXIT
to exit the program options, if needed.
2. Press
Speaker
.
Saving System Data is displayed if changes were made
to system programming.
3. The display shows Complete Data Save when
completed and the telephone becomes idle.
2.6.3.5
Backing Up/Restoring a Database
As a precaution, it is recommended that the customer
database be saved prior to updating the system software.
There are two methods of saving the database – either
using the PCPro application or saving directly to USB
Memory on GCD-CP10. Using PCPro, download the
database and save the file on the PC hard drive. To save
the database using a blank USB Memory, insert the USB
Memory into the USB Port on the GCD-CP10 blade and,
using Program 90-03, save the software. Due to the file
naming structure, note that a USB Memory can only hold
one customer database (each database is saved to a
directory called DATA – this directory is overwritten if a
second database is saved to the same card). Each
database to be saved will require its own separate card
(unless you choose to rename the directory after it is saved,
then rename it back to DATA when you need to access the
database).
If the customer data needs to be reloaded, the method for
restoring the database is determined by how the database
was saved. Using PCPro, the customer database is
uploaded using the Upload option within the application. If
the database is stored on a USB Memory, use Program
90-04, with the database to be restored installed in the USB
Port on the GCD-CP10 blade.
When restoring a database file, as the slot definitions may
be different, remove all blades from the system except the
GCD-CP10 and the GCD-8DLCA/GCD-16DLCA in slot 2.
After the system has been reset, blades can be reinstalled.
Program 10-03 or Program 90-04 can be used prior to
updating to record the current slot definitions. If the blades
are not removed, the trunk and extension port assignments
may be reassigned, depending on which blade syncs up
with the system first.
Summary of Contents for Univerge SV9100
Page 1: ...System Hardware Manual Issue 1 2 January 2015...
Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 40: ...Issue 1 2 UNIVERGE SV9100 1 16 Introduction to SV9100...
Page 105: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 3 33 Figure 3 42 Brackets Small Batt Box...
Page 154: ...Issue 1 2 UNIVERGE SV9100 3 82 Installing the SV9100 Chassis...
Page 239: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 4 85 Figure 4 24 Control Signal Connection...
Page 259: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 4 105 NOTES...
Page 260: ...Issue 1 2 UNIVERGE SV9100 4 106 Installing the SV9100 Blades...
Page 412: ...Issue 1 2 UNIVERGE SV9100 5 152 Installing DT Series Digital and IP Multiline Terminals...
Page 476: ...Issue 1 2 UNIVERGE SV9100 6 64 Installing SV9100 Optional Equipment...