![background image](http://html1.mh-extra.com/html/nec/univerge-sv9100/univerge-sv9100_hardware-manual_3936970167.webp)
UNIVERGE SV9100
Issue 1.2
System Hardware Manual
4 - 13
After reloading the customer data to the system, exit
programming mode (this could take a minute or more to
save the database),
then reset the system by powering
down and back up.
If the system is not reset, not all the
uploaded programming changes are in effect. Wait a few
minutes for the programming to take affect before accessing
any line or special system feature. Otherwise, some unusual
LED indications may be experienced. To prevent the USB
Memory from possibly being overwritten, remove the card
after reloading the database.
2.6.4
Performing a Software Upgrade
This section describes the procedure to perform a software upgrade
on the GCD-CP10.
To save customer data prior to updating, a blank USB
Memory is required. Insert the USB Memory into the
USB Port on the GCD-CP10 blade. Use Program 90-03
to save the software to the USB Memory. Note that a USB
Memory can only hold one customer database. Each
database to be saved requires its own separate USB
Drive. Use Program 90-04, with the database to be
restored installed in the GCD-CP10, to reload the
customer data if necessary.
After uploading programming data to the system using
Program 90-04, exit programming mode (this could take
a minute or more to save the database), then reset the
system by powering down and back up. Wait a few
minutes for the programming to take affect before
accessing any line or special system feature. Otherwise
some unusual LED indications may be experienced. To
prevent the USB Memory from possibly being
over-written, remove the USB Memory after downloading
the database.
When restoring a database file, as the slot definitions
may be different, remove all blades from the system
except the GCD-CP10 and GCD-8DLCA/GCD-16DLCA
in slot 2. After the system is reset, the blades can be
reinstalled. Use Program 10-03 prior to updating to
record the current slot definitions.
IMPORTANT CONSIDERATIONS
Summary of Contents for Univerge SV9100
Page 1: ...System Hardware Manual Issue 1 2 January 2015...
Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 40: ...Issue 1 2 UNIVERGE SV9100 1 16 Introduction to SV9100...
Page 105: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 3 33 Figure 3 42 Brackets Small Batt Box...
Page 154: ...Issue 1 2 UNIVERGE SV9100 3 82 Installing the SV9100 Chassis...
Page 239: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 4 85 Figure 4 24 Control Signal Connection...
Page 259: ...UNIVERGE SV9100 Issue 1 2 System Hardware Manual 4 105 NOTES...
Page 260: ...Issue 1 2 UNIVERGE SV9100 4 106 Installing the SV9100 Blades...
Page 412: ...Issue 1 2 UNIVERGE SV9100 5 152 Installing DT Series Digital and IP Multiline Terminals...
Page 476: ...Issue 1 2 UNIVERGE SV9100 6 64 Installing SV9100 Optional Equipment...