- use PO
to offset the formation on 3 axes, without changing the form itself.
-
ARRANGE IN CIRCLE:
Select fixtures
Set starting and end angles; between 0 and 360 or more
Set the starting and finishing radius (if the two radi are unequal, a spiral will be the result, see graphics on
the left)
- use PO
to offset the formation on 3 axes, without changing the form itself.
-
STRETCH POSITION:
Select fixtures
Use Total Factor to change the magnitude of the complete figure without changing its proportion
- the value Total Factor = 0 will place all fixtures in one point.
Use Factor X, Y and Z to change the figure's proportion on the chosen axis (see graphics on the left, the circle
has been modified to an oval)
- the value 0 will yield a straight line on the respective axis;
- use PO
to offset the formation on 3 axes, without changing the form itself.
-
CALCULATE FOLLOW:
With this function, you can transfer the real fixtures' positions to the SETUP of the grandMA console. The STAGE view
will then display the actual position of the fixtures to the stage. This light setting procedure should always be
performed, if it is not clear whether or not fixture positions had been exactly defined in the SETUP eingetragen
wurde. Important for the FOLLOW FUNCTION.
Define the light setting frame:
On the stage, mark the corners of a sqaure (light setting frame)
Enter the stage dimensions in SETUP / FULL ACCESS / STAGE SETUP.
Enter the dimensions of the light setting frame and its position relatively to the stage as such in the STAGE
CALIBRATION menu. The frame will appear as green square in the STAGE window
Move the first fixture to point A of the stage (using the Encoder or track ball);
Press STORE and Button A of the menu
Move the fixture to B,C, and D and press STORE plus the respective button when you reach these points
Repeat this procedure for all fixtures
Then press the CALCULATE button. The true fixture positions will be inserted into the SETUP menu and the