Moving Heads or Scanners are hanging in 90°
or 180° angles on the traverse - what do I have
to consider when using the PAN / TILT function?
When loading a new show (from the hard disk),
the console will freeze showing the message
REBOOTING - PLEASE WAIT. After resetting
(using the yellow button on the rear side of the
console), the show will load.
When starting a sequence (using the Executor
button or the Executor fader), the fixtures will
not light up on the stage, but the Channel
Sheet shows some values (nothing in the
STAGE window).
When loading a show from floppy that had
been created on another console, no fixtures
will appear.
are placed on moved positions, no or the wrong
channels will be triggered.
Choose SETUP / FULL ACCESS / in FIXTURE LAYER
the group to which this fixture belongs; in the
menu below, you can find the starting number
of this fixture – it has to correspond to the
address adjustable on the fixture.
e.g. on the console B17 = on the fixture 017
If the fixture has 14 channels, the next fixture
must beginn with B31.
Adapt the fixtures using the parameters X*, Y*
and Z* in SETUP / FULL ACCESS - if needed, use
INVERT to adjust the sense of rotation of PAN
and TILT.
It is highly probable that a software error has
occurred on the hard disk. Repairs should be
performed by a service technician, see hotline
contact on the bottom margin.
Master open ?/ Group master open?
If in the Channel / Fader and Fixture Sheet the
ID numbers or the names have a blue
background, the master has a subordinate
priorit
y
.
World assigned correctly?