Hotline: +49 5251 688865-99
Hotline: +49 5251 688865-99
Hotline: +49 5251 688865-99
Hotline: +49 5251 688865-99
Hotline: +49 5251 688865-99
. Operating Manual grandMA Version 5.4
175
175
175
175
175
Note: It is nearly impossible to use this command by typing it into the command line. Rather
use it when it is assigned to a button or in a Macro! TEMP does not really exist as a function.
It is always translated into a pair of GO/OFF commands. You will see that if you record TEMP
in a timecode show.
THRU
THRU
THRU
THRU
THRU
Classification
Classification
Classification
Classification
Classification
: helping keyword
THRU
THRU
THRU
THRU
THRU
can only be used within other commands to create ranges.
XXXXX
THRU Y
THRU Y
THRU Y
THRU Y
THRU Y
Range from X to Y
XXXXX
THRU
THRU
THRU
THRU
THRU
Range from X to the end
THRU Y
THRU Y
THRU Y
THRU Y
THRU Y
Range from the beginning to Y
THRU
THRU
THRU
THRU
THRU
Range from the beginning up to the end.
The meaning of “beginning” and “end” depend on the context:
FIXTURE 10 THRU ENTER
FIXTURE 10 THRU ENTER
FIXTURE 10 THRU ENTER
FIXTURE 10 THRU ENTER
FIXTURE 10 THRU ENTER
will select all fixtures from 10 upwards.
Thru can of course also be used to create ranges of values like
CHANNEL 1 THRU 10 AT 0 THRU FULL ENTER
CHANNEL 1 THRU 10 AT 0 THRU FULL ENTER
CHANNEL 1 THRU 10 AT 0 THRU FULL ENTER
CHANNEL 1 THRU 10 AT 0 THRU FULL ENTER
CHANNEL 1 THRU 10 AT 0 THRU FULL ENTER
Pushing this button will select the executor of the button as default executor.
SEQU
SEQU
SEQU
SEQU
SEQU
Classification
Classification
Classification
Classification
Classification
: object keyword
a) as starting keyword:
a) as starting keyword:
a) as starting keyword:
a) as starting keyword:
a) as starting keyword:
SEQU ENTER
SEQU becomes the DEFAULT KEYWORD.
SEQU (range list) ENTER
Select devices included in sequences.
Sequence numbers must be in the range of [ 1…999]
SEQU (range list) AT … (see AT)
Apply values to devices included in sequences.
b) as target for the following operational commands:
b) as target for the following operational commands:
b) as target for the following operational commands:
b) as target for the following operational commands:
b) as target for the following operational commands:
EDIT
Opens edit menu for sequence
IF
Deselect devices which are not part of the sequence.
IFOUTPUT
Search for stage output of sequence
INVERT
Invert selection of sequence
LABEL
Change name of sequence
MOVE
Move sequence to another position
c) as target for the following executing commands:
c) as target for the following executing commands:
c) as target for the following executing commands:
c) as target for the following executing commands:
c) as target for the following executing commands:
ON
“Knock in” all devices contained in sequence.
OFF
“Knock out” all devices contained in sequence.
PAUSE
PARK all devices contained in sequence.
GO
UNPARK all devices contained in sequence.
STORE
STORE
STORE
STORE
STORE
Classification
Classification
Classification
Classification
Classification
: operational keyword
STORE (object list) [ENTER]
STORE (object list) [ENTER]
STORE (object list) [ENTER]
STORE (object list) [ENTER]
STORE (object list) [ENTER]
All objects in the object list must be of the same type.
If no object is given, a new cue is stored into the default executor.
If the destination of the store command is not empty, you will be asked for confirmation.
In case of storing over existing cues, you will furthermore be asked about the desired store
mode. e.g. merge, overwrite or remove.
If you start storing by pressing the ST
If you start storing by pressing the ST
If you start storing by pressing the ST
If you start storing by pressing the ST
If you start storing by pressing the STORE hard key
ORE hard key
ORE hard key
ORE hard key
ORE hard key, a temporary
, a temporary
, a temporary
, a temporary
, a temporary
window will appear
window will appear
window will appear
window will appear
window will appear.....
The settings in this window affect the way , the store command is handled.
Defaults for these store options can be found in SETUP / DEFAULTS menu.
SWOP
SWOP
SWOP
SWOP
SWOP
Classification
Classification
Classification
Classification
Classification
: executing keyword
a) As starting keyword
a) As starting keyword
a) As starting keyword
a) As starting keyword
a) As starting keyword
, every executor that follows after SWOP increases the
intensity of all programmed dimmer channels to 100% while reducing all other executors
to 0% ( as long they are not protected against swop).
SWOP (executor list) [ENTER]
SWOP (executor list) [ENTER]
SWOP (executor list) [ENTER]
SWOP (executor list) [ENTER]
SWOP (executor list) [ENTER]
b) As starting keyword
b) As starting keyword
b) As starting keyword
b) As starting keyword
b) As starting keyword
combined with
UNPRESS
UNPRESS
UNPRESS
UNPRESS
UNPRESS
, every executor that follows after
SWOP reduces the intensity of all programmed dimmer channels to 0% while restoring the
intensity of
all other executors to 100%
SWOP (executor list) UNPRESS [ENTER]
c) In an assign command
c) In an assign command
c) In an assign command
c) In an assign command
c) In an assign command
, this function can
NOT
NOT
NOT
NOT
NOT
be used. You have to use the Assign
menu to define it on an executor´s button.
Note: It is nearly impossible to use this command by typing it into the command line. Use it
when it is assigned to a button or as part of a macro!
SWOP_OFF
SWOP_OFF
SWOP_OFF
SWOP_OFF
SWOP_OFF
Classification
Classification
Classification
Classification
Classification
: executing keyword
Same as
SWOP … UNPRESS.
SWOP … UNPRESS.
SWOP … UNPRESS.
SWOP … UNPRESS.
SWOP … UNPRESS.
Please look at the
SWOP
SWOP
SWOP
SWOP
SWOP
command description.
TEMP
TEMP
TEMP
TEMP
TEMP
Classification
Classification
Classification
Classification
Classification
: executing keyword
a) As starting keyword
a) As starting keyword
a) As starting keyword
a) As starting keyword
a) As starting keyword
, every executor that follows after TEMP performs a GO if it
wasn´t already running..
TEMP (executor list) [ENTER]
b) As starting keyword
b) As starting keyword
b) As starting keyword
b) As starting keyword
b) As starting keyword
combined with
UNPRESS
UNPRESS
UNPRESS
UNPRESS
UNPRESS
, every executor that follows after
TEMP is switched OFF.
TEMP (executor list) UNPRESS [ENTER]
c) In an assign command
c) In an assign command
c) In an assign command
c) In an assign command
c) In an assign command
, this function can be assigned to an executor´s button.
ASSIGN TEMP (executor list) ENTER
ASSIGN TEMP (executor list) ENTER
ASSIGN TEMP (executor list) ENTER
ASSIGN TEMP (executor list) ENTER
ASSIGN TEMP (executor list) ENTER