HLP-A100 Series Operating Manual
HLP-A100 Series
-
34
-
Item Parameter
No.
Function
Description
Setting range
Unit
Default
setting
Page
No.
Pa
ram
ete
r G
rou
p
04:
Lim
its/
W
arn
ing
s
C04.30
Motor
Feedback Loss
f unction
0: No f unction;
1: Freeze output;
3: Jog; 4: Max. Speed;
5: Stop and trip;
11: Switch to open
loop;
4
82
C04.31
Motor
Feedback
Speed Error
0~600
rpm
300
82
C04.32
Motor
Feedback Loss
Timeout
0.00~60.00
s
0.05
82
C04.50 Warning
Current Low 0.00~Imax
A
0.00
83
C04.51 Warning
Current High 0.00~Imax
A
83
C04.52 Warning
Speed Low
0.0~400.0
Hz
0.0
83
C04.53 Warning
Speed High
0.1~400.0
Hz
65.0
83
C04.54
Warning
Reference
Low
-4999.000~4999.000
0.000
83
C04.55
Warning
Reference
High
-4999.000~4999.000
50.000
84
C04.56
Warning
Feedback Low -4999.000~4999.000
0.000
84
C04.57
Warning
Feedback
High
-4999.000~4999.000
50.000
84
*C04.58
Missing
Motor Phase
Function
0: Off; 1: On;
1
84
C04.61
Bypass Speed
From [Hz]
0.0~400.0
Hz
0.0
84
C04.63
Bypass Speed
To [HZ]
0.0~400.0
Hz
0.0
85