These instructions form part of the product and must be observed. They must also be stored in a place which is always freely 
accessible. The copyright for these operating instructions is held solely by KACO new energy GmbH. 

 

Application note – Installation and using APP 

 

English version 

 

 

 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  

 

 

 

   

 

 

 

Authorised electrician 

Important safety instructions 

 
 

 

 

Android-APP 

iOS-APP 

KACO blueplanet 3.0 NX1 M2 
KACO blueplanet 3.7 NX1 M2 
KACO blueplanet 4.0 NX1 M2 
KACO blueplanet 5.0 NX1 M2

 

Summary of Contents for blueplanet 3.0 NX1 M2

Page 1: ...ble The copyright for these operating instructions is held solely by KACO new energy GmbH Application note Installation and using APP English version Authorised electrician Important safety instructio...

Page 2: ...tage protection 12 2 2 6 Inverter gird parameter setting frequency protection 13 2 2 7 Inverter gird parameter setting reconnection time 14 2 2 8 Inverter active power setting power limit 15 2 2 9 Inv...

Page 3: ...tspot via SSID and password in QR code so the app needs certain authorisations to access the device of the smart phone as below Access the device of smart phone 1 Photo and media permission 2 Location...

Page 4: ...ne s camera 2 Scan the QR code label on Wi Fi stick then the tool app will automatically connect to Wi Fi stick s hotspot 3 Click the Select network button choose the Wi Fi SSID of the nearby router p...

Page 5: ...to connect to another router Connect to another router 1 Connect the smart phone to the router through Wi Fi and open the tool app click the LOCAL MODE button 2 Enter the Monitor Device Details page a...

Page 6: ...low Time zone configuration setting 1 Open the tool app and click the INSTALLATION button The tool app will open the phone s camera 2 Scan the QR code label on Wi Fi stick then the tool app will autom...

Page 7: ...ID in WLAN list of your smart phone The password of the Wi Fi stick s hotspot is the registration code on the Wi Fi stick Connect Wi Fi stick directly through the Wi Fi stick s hotspot 1 Open the phon...

Page 8: ...WLAN list Sometimes you can t find the smart Wi Fi dongle in your WLAN list Sometimes you can t find the smart Wi Fi dongle in your WLAN list You need to check the network of your phone is the same a...

Page 9: ...ration 3 Loosen the swivel nut of the cable gland on the communication plate 4 Remove the sealing plug and lead the stripped cable through the swivel nut sealing sleeve communication plate and the cab...

Page 10: ...m NOTE The smart meter should support the MODBUS protocol with a baud rate of 9600 and address set 1 2 2 Inverter parameters settings 2 2 1 Connect to inverter Connect to the Wi Fi stick with the tool...

Page 11: ...nverters connected to the Wi Fi stick You have removed a single inverter multiple inverters connected to the Wi Fi stick You have replaced a single inverter multiple inverters connected to the Wi Fi s...

Page 12: ...bling them as shown below Fig 22 Inverter function enable disable 2 2 3 Inverter gird parameter setting grid standards The currently selected country standard is displayed on the right side of Country...

Page 13: ...5 0 NX1 M2 2 2 4 Inverter gird parameter setting power up Tap Parameter Settings For Starting the next page will display the parameter The appropriate voltage range and frequency range for starting c...

Page 14: ...tage and undervoltage protection The first threshold means the smallest range and the third threshold means the largest range All thresholds need to follow the principles as below 1 The first maximum...

Page 15: ...uency and underfrequency protection The first threshold means the smallest range and the third threshold means the largest range All thresholds need to follow the principles as below 1 The first maxim...

Page 16: ...parameter setting reconnection time Tap Reconnection Time Settings the next page will display the parameter The observation time during which all the voltage and the frequency values are observed to b...

Page 17: ...operation the active power generated by the inverter shall not exceed a specified gradient expressed as a percentage of the active nominal power of the inverter per minute You can set Active power gra...

Page 18: ...ariable gradient and non hysteresis P is the active power as a percentage of PM the inverter provide non hysteresis in the control of active power response to over frequency Variable gradient and hyst...

Page 19: ...Page 17 KACO blueplanet 3 0 NX1 M2 KACO blueplanet 3 7 NX1 M2 KACO blueplanet 4 0 NX1 M2 KACO blueplanet 5 0 NX1 M2 Fig 29 Over frequency curve...

Page 20: ...Variable gradient and non hysteresis P is the active power as a percentage of PM the inverter provide non hysteresis in the control of active power response to overvoltage Variable gradient and hyste...

Page 21: ...Page 19 KACO blueplanet 3 0 NX1 M2 KACO blueplanet 3 7 NX1 M2 KACO blueplanet 4 0 NX1 M2 KACO blueplanet 5 0 NX1 M2 Fig 30 Over voltage curve...

Page 22: ...the country standard This means the inverter operation in Quadrant II under excited or III overexcited as below Over excited reactive power also kwon as Capacitive reactive power or Leading power fac...

Page 23: ...t 3 0 NX1 M2 KACO blueplanet 3 7 NX1 M2 KACO blueplanet 4 0 NX1 M2 KACO blueplanet 5 0 NX1 M2 2 2 12Inverter reactive power setting fixed power factor The fixed displacement factor cos can be set Fig...

Page 24: ...nts that can be adjustable in the curve as below figure The coordinate points are the active power as a percentage of Pn and the displacement factor cos Some grid company maybe requires two voltage th...

Page 25: ...planet 3 0 NX1 M2 KACO blueplanet 3 7 NX1 M2 KACO blueplanet 4 0 NX1 M2 KACO blueplanet 5 0 NX1 M2 2 2 14Inverter reactive power setting fixed Q The fixed reactive power as a percentage of Pn can be s...

Page 26: ...e between non hysteresis and hysteresis control shown as below figure The coordinate points are the voltage as a percentage of Un and the reactive power as a percentage of Pn Some grid company maybe r...

Page 27: ...ess Inverter Parameter Report menu and gird parameter will be shown on page 2 Press Export PDF button the export file is located as a pdf file in kaco report folder on your smart phone Fig 36 Paramete...

Page 28: ...the inverter serial number Proceed with inverter real time data Fig 37 Connect to inverter NOTE Scan device in Inverter List page Under normal circumstances you do not need to search for devices You...

Page 29: ...ollow Parameter Description PV1 Voltage and current of MPPT 1 at DC side PV2 Voltage and current of MPPT 2 at DC side U1 Voltage and current at AC side E Today Generation today E Total Cumulative powe...

Page 30: ...Device Details page click the Zero Export Setting item 2 Choose the smart meter model If the inverter is NX1 choose SDM230 If the inverter is NX3 choose SDM630 3 Click the Meter Switch and the Enable...

Page 31: ...s Software 2 Unzip the firmware to the mobile device and open the KACO NX1 APP 3 Scan the QR code on the Wi Fi stick log in and select the device in the network 4 On the Monitor Device Details page cl...

Page 32: ...e Inverter and select the device 4 Click on Local upgrade under Master and select the filei masterVxxx xxxxx xx bin from the firmware path 5 Click on Local upgrade under Safety and select the file saf...

Page 33: ...Werner von Siemens Allee 1 74172 Neckarsulm Germany Tel 49 7132 3818 0 info kaco newenergy de www kaco newenergy de 3014901 04 220708...