HLP-A100 Series Operating Manual
HLP-A100 Series
-
84
-
C04.55 Function Description
Range
Unit
Default
Setting
Warning Reference High -4999.000~4999.000
50.000
Function: Enter the upper reference limit, when the actual reference exceeds
this limit, the display reads Ref High.
C04.56
Function Description
Range
Unit
Default
Setting
Warning Feedback Low -4999.000~4999.000
0.000
Function: Enter the lower feedback limit, when the feedback falls below this
limit, the display reads Feedb Low.
C04.57
Function Description
Range
Unit
Default
Setting
Warning Feedback High -4999.000~4999.000
50.000
Function: Enter the upper feedback limit, when the feedback exceeds this limit,
the display reads Feedb High.
Option: [0] Off, f unctoin is disabled;
[1] On, f unction is enabled;
Attention: Missing motor phase causes motor torque to decrease. This f unction
*C04.58 Function Description
Range
Unit
Default Setting
Missing Motor Phase
Function
0~1
1
C04.53 Function Description
Range
Unit
Default Setting
Warning Speed High
0.1~400.0
Hz
65.0
Function: Enter the n
high
value, when the motor speed exceeds this limit, the
display reads Speed High.
Attention: This setting must be within normal motor f requency range,
otherwise, it may trigger an error warning.
C04.54 Function Description
Range
Unit
Default
Setting
Warning Reference Low -4999.000~4999.000
0.000
Function: Enter the lower reference limit, when the actual reference falls
below this limit, the display indicates Ref Low.