HLP-A100 Series Operating Manual
HLP-A100 Series
-
32
-
Item Parameter
No.
Function
Description
Setting range
Unit
Default
setting
Page
No.
Pa
ram
eter
G
rou
p 0
3: R
efer
en
ce/
R
am
ps
C03.03 Maximum
Reference
-4999.000~4999.000
50.000
72
C03.07
Main
reference
calculation
0: Preset ref
Reference source 1,2
1: Preset reference
priority
0
C03.10 Preset
Reference
-100.00~100.00
%
0.00
73
C03.11
Jog Speed [Hz]
0.0~400.0
Hz
5.0
74
C03.12 Catch up/slow
Down Value 0.00~100.00
%
0.00
74
C03.13
SpeedUp/
Down Value 0.01~50.00
Hz
0.10
74
C03.14
Preset
Relative
Reference
-100.00~100.00
%
0.00
75
C03.15 Reference
Resource 1
0: No f unction;
1: Analog input VI;
2: Analog Input AI;
8: Pulse input;
11: Local bus ref;
21: LCP
potentiometer;
1
75
C03.16
Reference
Resource 2
2
75
C03.17
Reference
Resource 3
11
75
C03.18
Relative
Scaling
Reference
Resource
0
76
C03.19
Save Speed
Up/Down
Value
0: No f unction;
1: Stopsave; 2: Power
down save;
0
76
C03.40 Ramp 1 Type
0: Linear; 2: Sine2
ramp;
0
76
C03.41 Ramp 1 Ramp
up Time
0.05~3600.00
s
*
77
C03.42 Ramp 1 Ramp
Down Time
0.05~3600.00
s
*
78
C03.50 Ramp 2 Type
0: Linear; 2: Sine2
ramp;
0
78
Summary of Contents for HLP-A100 Series