C30.13 Function Description
Range
Unit
Default Setting
Delta Frequency Mode
0~1
0
Option: [0]: Relative to speed high;
[1]: Relative to center f requency; delta can change with the center
f requency. The relative percentage will be set in C30.14.
Function: If [0] is selected, f
delta
=Delta Frequency Percentage*Motor
Speed High Limit/100; If [1] is selected, f
delta
=Delta Frequency
Percentage*Center Frequency/100.
C30.14 Function Description
Range
Unit
Default Setting
Delta Frequency Percentage
0~100
%
0
Function: Enter the value of the Delta Frequency Percentage.
C30.15 Function Description
Range
Unit
Default Setting
Jump Frequency Percentage
0~100
%
0
Function: Enter value of the Jump Frequency Percentage. The jump
f requency f jump =fdelta*Jump Frequency Percentage
C30.16
Function Description
Range
Unit
Default Setting
Wobble Up Time
1.0~1000.0
s
10.0
Function: During the wobble cycle, this parameter used to set the time within
which the drive ramp up to the wobble up (f fdelta) .
C30.17
Function Description
Range
Unit
Default Setting
Wobble Jump Time
1~50
ms
1
Function: Set the jump time within which the drive ramp down by Jump
Frequency .
C30.18 Function Description
Range
Unit
Default Setting
Wobble Down Time
1.0~1000.0
s
10.0
Function: During the wobble cycle, this parameter used to set the time within
which the drive ramp down to wobble down reference (fcenter -
fdelta).
Frequency Decreasing Rate”(C30.10) till “Center Frequency Low
Limit reached.When decreasing, there is no transition process, the
drive runs directly under the new f requency.