HLP-A100 Series
HLP-A100 Series Operating Manual
-
39
-
Item Parameter
No.
Function
Description
Setting range
Unit
Default
setting
Page
No.
Pa
ram
ete
r G
rou
p
05:
D
igit
al I
n/O
ut
C06.01
Live Zero
Timeout
Function
0: Off; 1: Freeze
output; 2: Stop;
3: Jogging; 4: Max.
speed; 5: Stop and
Trip;
0
94
C06.10
Terminal VI
Low Voltage 0.00~9.99
V
0.07
95
C06.11
Terminal VI
High Voltage 0.10~10.00
V
10.00
95
C06.12
Terminal VI
Low Current 0.00~19.99
mA
0.14
95
C06.13
Terminal VI
High current 0.01~20.00
mA 20.00
95
C06.14
Terminal VI
Low Ref./
Feedb.Value
-4999.000~4999.000
0.000
95
C06.15
Terminal VI
High Ref./
Feedb.Value
-4999.000~4999.000
50.000
96
C06.16
Terminal VI
Filter Time
Constant
0.01~10.00
s
0.01
96
C06.18
Terminal VI
Zero dead
band
0.00~20.00
V/
mA
0.00
96
C06.19
Terminal VI
Mode
0: Votage mode;
1: Current mode;
0
97
C06.20
Terminal AI
Low Voltage 0.00~9.99
V
0.07
97
C06.21
Terminal AI
High voltage 0.01~10.00
V
10.00
97
C06.22
Terminal AI
Low Current 0.00~19.99
mA
0.14
97
C06.23
Terminal AI
High Current 0.01~20.00
mA 20.00
98
C06.24
Terminal AI
Low Ref./
Feedb.Value
-4999.000~4999.000
0.000
98