HLP-A100 Series Operating Manual
HLP-A100 Series
-
102
-
C06.82
Function Description
Range
Unit
Default
Setting
LCP Potmeter High Ref. -4999.000~4999.000
50.000
Function: This reference value corresponding to potentiometer turned f ully
clockwise.
Option: [0] 0-20mA;
[1] 4-20mA;
Function: Select the current output signal type of analog output terminal AO.
C06.9* Analog Output AO
C06.90
Function Description
Range
Unit
Default Setting
Terminal AO Mode
0~2
0
Option: See C06.71.
Function: Select choices of analog output VO.
C06.91
Function Description
Range
Unit
Default Setting
Terminal AO Analog
Output
0~23
0
Function: Scale minmum output of selected analog signal at terminal AO as
percentage of maximum signal value. See fig. below:
C06.93
Function Description
Range
Unit
Default Setting
Terminal AO Output
Min. Scale
0.00~200.00
0.00