background image

 

 
 

 

 

Pure Sine Wave Inverter

 

User Manual

 

IP350-12/22/11/21 

IP500-12/22/11/21 

IP1000-12/22/11/21 

IP1500-12/22/11/21 

IP2000-22/42/21/41 

Summary of Contents for IP1000-11

Page 1: ...Pure Sine Wave Inverter User Manual IP350 12 22 11 21 IP500 12 22 11 21 IP1000 12 22 11 21 IP1500 12 22 11 21 IP2000 22 42 21 41...

Page 2: ......

Page 3: ...TS 1 Important Safety Instructions 1 2 Introduction 3 3 Designations of models 4 4 Wiring 5 5 Functions 7 6 Protection 11 7 Troubleshooting 13 8 Maintenance 14 9 Disclaimer 15 10 Technical Specificati...

Page 4: ...ep normal inverter operation Use a DC power supply for testing may cause damage to the inverter When the inverter works continuously its surface may become very hot please ensure the air ventilation c...

Page 5: ...ctric shock don t touch the output port when the inverter is working The output is forbidden to connect to other power sources or grid otherwise the inverter will be damaged The inverter must be turne...

Page 6: ...electrical isolation Adoption of advanced SPWM technology pure sine wave output Optional output voltage 220 230VAC or 110 120VAC choosing by DIP switch LED indicators for fault status and working stat...

Page 7: ...1 12VDC 110 120VAC 350W IP350 21 24VDC 110 120VAC 350W IP500 11 12VDC 110 120VAC 500W IP500 21 24VDC 110 120VAC 500W IP1000 11 12VDC 110 120VAC 1000W IP1000 21 24VDC 110 120VAC 1000W IP1500 11 12VDC 1...

Page 8: ...utput Operation Steps Step 1 Turn the power switch of the inverter to OFF Step 2 Disconnect the input breaker or the fuse between the inverter and battery connect the battery terminals with the red li...

Page 9: ...the operation state of the inverter and loads Step 6 If there are different types of loads the loads with higher startup current should be turned on firstly such as television After the loads work sta...

Page 10: ...ication port 4 DC input voltage range 1 USB output port 5VDC 1A DC Input Terminal Negative AC output switch Ventilation Fan 2 Mode switch 5 Grounding Terminal Fault indicator red 6 AC Outlet 3 Working...

Page 11: ...n the heat sink temperature is higher than 50 or the internal temperature is higher than 50 the fan will turn on automatically When the heat sink temperature is lower than 40 and the internal temperat...

Page 12: ...models optional The RJ45 interface pin definition is shown below 5 Mode Switch When switch No 1 is on the ON side the output frequency is 60Hz Otherwise it is 50Hz When switch No 2 is on the ON side t...

Page 13: ...g indicator Fault indicator Buzzer Status Green On Solid Red OFF No Sounding Output is normal Green Slowly Flashing 1 4Hz Red OFF Sounding Input under voltage Green Fast Flashing 1Hz Red OFF Sounding...

Page 14: ...6V Ui 43 2V Output is OFF Green indicator slowly flashing Buzzer sounds Ui 12 5V Ui 25V Ui 50V Green indicator on solid The output is on Over tem protection and recover Tem T Heat sink T 80 IP1000 T 7...

Page 15: ...n output overload protection or load short circuit protection is activated the AC output would auto recovery three times the first time delays for 5s the second time delays for 10s and the third time...

Page 16: ...Adjust the input voltage to restore normally Red indicator slowly flashing Buzzer sounds Overload Reduce the number of AC loads Restart the inverter Red indicator fast flashing Buzzer sounds Short ci...

Page 17: ...y troubleshooting or error indication Take corrective action if necessary Confirm that all the terminals have no corrosion insulation damaged high temperature or burnt discolored sign tighten terminal...

Page 18: ...e or use in an inappropriate environment Battery voltage exceeds the input voltage limit of the inverter Damage caused by working environment temperature exceeds the rated range Unauthorized dismantli...

Page 19: ...sine wave Distortion THD THD 5 THD 3 THD 5 THD 3 Max Efficiency 90 91 91 92 No load current 0 7A 0 5A USB Output Port 5VDC Max 1A Binding post 6mm Overall dimension 214 105 5 57 7mm Mounting dimensio...

Page 20: ...Resistive load Conventional products don t have this port the port is optional Item IP1000 11 IP1000 12 IP1000 21 IP1000 22 Rated Input Voltage 12VDC 24VDC Input Voltage Range 10 8 16VDC 21 6 32VDC I...

Page 21: ...3 220VAC 5 230VAC 7 5 Output Frequency 50 60 0 1Hz Output Continuous Power 1200W Output Power 15 min 1500W Surge power 2400W Power factor 0 2 1 VA lower than output continuous power Output Wave Pure s...

Page 22: ...5VDC Max 1A RS485 Com Port 5VDC 200mA Binding Post 6mm Overall Dimension 326 12 231 5 98 5mm Mounting Dimension 208 219 5mm Mounting Hole Size 5 5mm Net Weight 4 6kg Test condition Rated Input Voltag...

Page 23: ...20 Any changes without prior notice Version number V2 1...

Page 24: ...HUIZHOU EPEVER TECHNOLOGY CO LTD Beijing Tel 86 10 82894896 82894112 Huizhou Tel 86 752 3889706 E mail info epsolarpv com Website www epsolarpv com www epever com...